6.3.7
Slip compensation
When Pr.407 Motor temperature detection filter "9999", slip compensation is enabled under vector control for the motor
with an encoder. The slip frequency is compensated by Pr.326 Motor temperature feedback reference and the detected
temperature.
When using the motor constant set by offline auto tuning or set directly, set in Pr.326 the motor temperature for when the motor
constant (R2) was determined.
Pr.
Pr.
group
Motor temperature feedback
*1
G062
326
reference
*1
Setting can be made only when the FR-A8AZ is mounted.
NOTE
• When Pr.407 "9999", magnetic flux observer under vector control for the motor with an encoder (Pr.95 Online auto
tuning selection = "2") is invalid.
Initial
Name
value
9999
Minimum
Setting
setting
range
increments
Set the motor temperature for when the
0 to 150
motor constant (R2) was determined.
1
The slip frequency is compensated with a
9999
reference temperature of 75.