Beckhoff CP29 Series Manual
Hide thumbs Also See for CP29 Series:
Table of Contents

Advertisement

Quick Links

Manual | EN
CP29xx
Control Panel
2024-03-12 | Version: 4.1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CP29 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Beckhoff CP29 Series

  • Page 1 Manual | EN CP29xx Control Panel 2024-03-12 | Version: 4.1...
  • Page 3: Table Of Contents

    Table of contents Table of contents 1 Notes on the documentation........................ 5 2 For your safety ............................ 6 Signal words............................ 6 Intended use .............................  6 Fundamental safety instructions .......................  7 Operator's obligation to exercise diligence.................. 7 Notes on information security...................... 8 3 Product overview ............................
  • Page 4 Table of contents Approvals ............................ 45 Version: 4.1 CP29xx...
  • Page 5: Notes On The Documentation

    Copyright © Beckhoff Automation GmbH & Co. KG. Publication of this document on websites other than ours is prohibited. Offenders will be held liable for the payment of damages. All rights reserved in the event of the grant of a patent, utility model or design.
  • Page 6: For Your Safety

    Exclusion of liability Beckhoff shall not be liable in the event of non-compliance with this documentation and thus the use of the devices outside the documented operating conditions.
  • Page 7: Fundamental Safety Instructions

    For your safety Fundamental safety instructions The following safety instructions must be observed when handling the device. Application conditions • Do not use the device under extreme environmental conditions. • Only use the device in hazardous areas if it is explicitly designed for this purpose. •...
  • Page 8: Notes On Information Security

    For your safety Notes on information security The products of Beckhoff Automation GmbH & Co. KG (Beckhoff), insofar as they can be accessed online, are equipped with security functions that support the secure operation of plants, systems, machines and networks. Despite the security functions, the creation, implementation and constant updating of a holistic security concept for the operation are necessary to protect the respective plant, system, machine and networks against cyber threats.
  • Page 9: Product Overview

    Product overview Product overview The Beckhoff Panel generation with industrially-compatible multi-touch display is designed for control cabinet installation. The devices offer suitable solutions for a variety of applications. The model variety ranges from different display sizes and formats to custom models. This Panel generation is also suited for single-touch applications.
  • Page 10: Structure

    Product overview Structure Figure 2 shows the device configuration as an example of all CP29xx versions. Depending on the product version, the interfaces of the control panel on the connection block vary. Otherwise, there are no differences in the external design of the device. 10 9 Fig. 2: Structure Table 1: Legend structure...
  • Page 11: Fig. 3 Structure Stainless Steel Device

    Product overview Fig. 3: Structure stainless steel device Table 2: Legend structure CP29xx stainless steel device Component Description Clamping lever Mounting the control panel in the control cabinet wall Silicone seal Protection of the connection section from moisture Name plate Information on the control panel equipment Access to interfaces Interfaces on the underside Display and touch screen glass...
  • Page 12: Cp29Xx-0000 Interface Description

    The plug is included in the delivery. You can obtain a replacement plug from your Beckhoff Sales using the following ordering option: • C9900-P927: power supply connector for CP29xx, 5-pin connector with strain relief for the external supply cable Version: 4.1...
  • Page 13: Fig. 5 Usb Interface Pin Numbering

    Product overview 3.2.2 USB output The CP29xx-0000 Control Panel has two USB outputs (X102, X103) with socket type A. The interfaces are used to connect peripheral devices with USB connection. USB specification 3.0 is supported for connection distances up to 3 m. USB specification 2.0 is supported for connection distances of more than 3 m or when USB-E is used.
  • Page 14: Usb Input

    Product overview 3.2.3 USB input The CP29xx-0000 Control Panel has a USB input (X104) with socket type B. The USB input is used to connect the control panel to the industrial PC. USB specification 3.0 is supported for connection distances up to 3 m.
  • Page 15: Usb Extended Input

    Product overview 3.2.4 USB Extended input The CP29xx-0000 Control Panel has a USB Extended input (X105) in the form of an RJ45 socket. The interface is used to connect the control panel to the CU8801 USB-to-USB extended transmitter box. The connection is made via a standard RJ45 cable, not crossed.
  • Page 16: Dvi Extended Input

    Product overview 3.2.5 DVI Extended input The CP29xx-0000 Control Panel has a DVI Extended input (X106). It is used to transmit the graphics signal from the industrial PC to the control panel. The graphics signal is transferred directly via a DVI cable over a distance of 50 m max. Such a cable length leads to strong distortion of the graphics signal on arrival at the control panel.
  • Page 17: Cp29Xx-0010 Interface Description

    The plug is included in the delivery. You can obtain a replacement plug from your Beckhoff Sales using the following ordering option: • C9900-P927: power supply connector for CP29xx, 5-pin connector with strain relief for the external...
  • Page 18: Usb Output

    Product overview 3.3.2 USB output The CP29xx-0010 Control Panel has two USB outputs (X102, X103) with socket type A. The interfaces are used to connect peripheral devices with USB connection. USB specification 2.0 is supported. X102 1 2 3 4 X103 Fig. 10: USB interface pin numbering Table 9: USB interface pin assignment...
  • Page 19: Cp-Link 4

    Product overview 3.3.3 CP-Link 4 The CP29xx-0010 Control Panel has a CP-Link 4 input (X104) in the form of an RJ45 socket. This is not an Ethernet port. Via the interface, the control panel can be connected to an industrial PC at a distance of up to 100 m.
  • Page 20: Fig. 13 Cp-Link 4, Cu8802

    Product overview If the industrial PC is not equipped with a PCIe module, a transmitter box is required for connecting a CP29xx-0010. The CU8802 transmitter boxes (Two Cable Display Link) and CU8803 (One Cable Display Link) are available for this purpose. When installing the CP29xx-0010 with the CU8802 transmitter box, the industrial PC is connected to the transmitter box via USB and DP/DVI.
  • Page 21: Fig. 14 Cp-Link 4, Cu8803

    Product overview C6032-00x0 with PCIe compact module for CP-Link 4 CP-Link 4 (100 m) CU8803-0000 DP to DVI CP-Link 4 (100 m) DP to DVI CP-Link 4 (100 m) Fig. 14: CP-Link 4, CU8803 The following ordering options are available for the transmitter boxes: •...
  • Page 22: Optional Usb Interface

    Product overview Optional USB interface You can expand the CP29xx beyond the basic configuration with an additional USB interface. The following ordering options are available: • USB (order identifier: C9900-E268) The ordering option is not available for the CP29xx in combination with a push button extension or a stainless steel front.
  • Page 23: Name Plate

    Product overview Name plate The name plate provides you with information on the equipment of the control panel. The name plate shown here is only an example. xxxxxxxx Fig. 17: Name plate example Table 12: Legend name plate Description Model: the last four digits indicate the product variant. Serial number (BTN) Date of manufacture Display...
  • Page 24: Connection Cables/Connection Kits

    Product overview Connection cables/connection kits Different connection cables or connection kits are available, depending on the product version. 3.6.1 CP29xx-0000 connection kits The following connection kits are available for the CP29xx-0000: Table 13: CP29xx-0000 connection kits Connection kits Description C9900-K622 1 m connection kit for CP29xx-0000, consisting of: 1 m DVI cable, 1 m USB 3.0 cable C9900-K623 3 m connection kit for CP29xx-0000, consisting of:...
  • Page 25: Cp29Xx-0010 Connection Cables

    Product overview 3.6.2 CP29xx-0010 connection cables The following connection cables are available for the CP29xx-0010: Table 14: CP29xx-0010 connection cables Connection cable Description C9900-K671 RJ45 connection cable CAT.6 , 3 m C9900-K672 RJ45 connection cable CAT.6 , 5 m C9900-K673 RJ45 connection cable CAT.6 , 10 m C9900-K674 RJ45 connection cable CAT.6...
  • Page 26: Commissioning

    You can either order a Beckhoff protective film individually and fit it yourself retrospectively, or you can order the film for fitting directly ex factory. Please refer to the price list for the available protective films according to the display size of your device.
  • Page 27: Transport And Unpacking

    4. Check your delivery for completeness by comparing it with your order. 5. Check the contents for visible shipping damage. 6. In case of discrepancies between the package contents and the order, or in case of transport damage, please inform Beckhoff Service (see Chapter 9.1 Service and support). CP29xx Version: 4.1...
  • Page 28: Installation In The Control Cabinet

    The device is designed for installation in the front of a control cabinet in machine and system engineering. The environmental conditions specified for operation must be observed. The dimensions of the control panel can be found in the download finder on the Beckhoff website under Technical drawings: https://www.beckhoff.com/downloadfinder.
  • Page 29: Fig. 18 Delivery State Clamping Lever

    Commissioning 4.2.1 Installation in the control cabinet Preparation of the control cabinet The control cabinet must have the required installation cutout according to the device dimensions of the control panel. The wall thickness must be between 1 mm and 5 mm for installation. After installation, be sure to check the tightness between the control panel and the installation wall.
  • Page 30: Fig. 19 Wall Positioning

    Commissioning Fig. 19: Wall positioning 2. Turn the clamping levers 90° outwards (sections A and B). 3. Tighten the clamping levers with the Allen key 3.0 mm (section C). ð You have mounted the control panel in the control cabinet. Fig. 20: Control cabinet installation Version: 4.1 CP29xx...
  • Page 31: Connecting The Control Panel

    Commissioning Connecting the control panel CAUTION Risk of electric shock Dangerous touch voltages can lead to electric shock. To avoid electric shock, observe the following: • Never connect or disconnect the device cables during a thunderstorm. • Provide protective earthing for handling the device. To make the device ready for operation, you have to connect it.
  • Page 32: Installing Power Supply Cable

    It consists of a 5-pin connection strip and a strain relief housing with cable tie. If you require a replacement for the voltage connector or the strain relief housing, you can order these from Beckhoff Sales using the following ordering option: • C9900-P927: power supply connector for CP29xx multi-touch built-in Control Panel, 5-pin connector...
  • Page 33: Fig. 22 Disassembly Of The Strain Relief Housing

    Commissioning ð You have removed the strain relief housing. Fig. 22: Disassembly of the strain relief housing CP29xx Version: 4.1...
  • Page 34: Grounding The Control Panel

    Commissioning 4.3.2 Grounding the control panel Potential differences are minimized and electrical currents are diverted to the ground through grounding or potential equalization of electronic devices. This is to prevent dangerous touch voltages and electromagnetic interference. Protective earth The protective grounding of a device serves to avoid dangerous touch voltages. According to the EN 60204-1 standard (Chapter 8 Potential equalization), protective grounding is required if: •...
  • Page 35: Connecting Cables And Power Supply

    Commissioning 4.3.3 Connecting cables and power supply NOTICE Incorrect connection procedure Incorrect procedure when connecting the cables and the power supply can cause hardware damage. • Follow the documented procedure for connecting the cables and the power supply. • Always connect the cables first and only then switch on the power supply. •...
  • Page 36: Shutting Down

    Shutting down Shutting down NOTICE Hardware damage due to power supply A connected power supply can cause damage to the device during disassembly. • Disconnect the power supply from the device before starting to disassemble it. When taking the control panel out of operation, you must first disconnect the power supply and cables. You can then remove the device from the control cabinet.
  • Page 37: Disassembly And Disposal

    Shutting down Disassembly and disposal Before you can remove the control panel from the control cabinet, you must first disconnect the power supply and the cables (see chapter 5.1 Disconnecting the power supply and cables [} 36]). To remove the control panel from the control cabinet, follow the steps shown in Fig. 24: 1.
  • Page 38: Servicing And Maintenance

    • cold water with a heated device • high water pressure, e.g. high-pressure cleaner Repair Only the vendor may repair the device. If a repair should be necessary, contact Beckhoff Service (see Chapter 9.1 Service and Support [} 44]). Version: 4.1...
  • Page 39: Cleaning The Front Screen

    You can clean the front screen of the device during operation. In order to avoid inadvertent touch entries when doing this, you must first set the device to "Cleaning Mode" with the help of the Beckhoff Control Tool. Also make sure that you not only clean the display area, but also the edge of the glass pane. Impurities in...
  • Page 40: Exchange Seal

    The silicone seal may become porous after a long operating time. In that case, you should replace the seal to continue protecting the connection section. You can order the following replacement seals from your Beckhoff sales department: Table 15: Ordering options seal...
  • Page 41: Fig. 28 Replacing Silicone Seal

    Servicing and maintenance Fig. 28: Replacing silicone seal CP29xx Version: 4.1...
  • Page 42: Troubleshooting

    Measures No control panel function Lack of power supply to the control Check the power supply cable panel Call Beckhoff Service Other cause The control panel only works Defective backlight in the display Call Beckhoff Service partially or only temporarily (e.g.
  • Page 43: Technical Data

    (24 V power supply unit, NEC class 2) Power consumption Data sheet for calculating power consumption and power loss in the download finder - Data sheets: http://www.beckhoff.com/downloadfinder Protection rating Front IP65, rear IP20 Vibration resistance (sinusoidal EN 60068-2-6: 10 ... 58 Hz: 0.035 mm...
  • Page 44: Appendix

    33415 Verl Germany Phone: + 49 5246/963-0 email: info@beckhoff.de The addresses of the worldwide Beckhoff branches and agencies can be found on our website at http:// www.beckhoff.com/. You will also find further documentation for Beckhoff components there. Version: 4.1 CP29xx...
  • Page 45 Appendix Approvals Your device has at least the following approvals: • CE • EAC • UKCA • FCC You will find all other applicable approvals on the name plate of your device. FCC approvals for the United States of America FCC: Federal Communications Commission Radio Frequency Interference Statement This device was tested and complies with the limits for a digital device of class A, according part 15 of the FCC regulations.
  • Page 46 List of figures List of figures Fig. 1 Without and with push button extension ..................Fig. 2 Structure............................Fig. 3 Structure stainless steel device....................Fig. 4 Voltage socket pin numbering...................... Fig. 5 USB interface pin numbering ....................... Fig. 6 USB input pin numbering ......................Fig.
  • Page 47 List of tables List of tables Table 1 Legend structure .......................... Table 2 Legend structure CP29xx stainless steel device................Table 3 Voltage socket pin assignment ....................Table 4 USB interface pin assignment...................... Table 5 USB interface pin assignment...................... Table 6 USB-E input pin assignment ......................Table 7 DVI Extended interface pin assignment ..................
  • Page 49 More Information: www.beckhoff.com/cp29xx Beckhoff Automation GmbH & Co. KG Hülshorstweg 20 33415 Verl Germany Phone: +49 5246 9630 info@beckhoff.com www.beckhoff.com...

This manual is also suitable for:

Cp2912Cp2913Cp2915Cp2916Cp2918Cp2919 ... Show all

Table of Contents