5.2.4 Installing DC SPD
1. Use PH2 screwdriver to tighten 18 screws on DC SPD with 0.8 N-m torque.
Please pay attention for tightening all screws correctly and PCB is not crooked.
2. Connect the sensing cable to the slot and ensure to be locked.
3. Mount protective cover and follow Section 5.1.3 to close front door to finish
SPD installation.
Figure 5-9: Remove sensing cable and screws
* Screw torque:
②
①
61
Maintenance
0.8 N•m