TROUBLESHOOTING

Problem
The values
displayed are not
as expected.
The value is not
displayed / Only
dashes displayed
Slow update rate on
NMEA data
27
Root cause
Incorrect sensor configuration.
Sensor connected incorrectly.
The NMEA 2000 network
backbone has not been
created correctly.
Not available on the network.
Sensor not connected.
The NMEA 2000 network
backbone has not been
created correctly.
The value is expected to be
received from the analog
input.
Check the configuration in the Sensors menu.
Check the connection, refer to the Installation
Instructions.
Check the connections and that there is a
termination at both the beginning and end of the
backbone.
Check that the sensor is functioning correctly.
Connect the sensor, refer to the
Instructions
.
Check the connections and that there is a
termination at both the beginning and end of the
backbone.
Disable the analog inputs when they are not being
used.
TROUBLESHOOTING
Solution
Installation
VMH 35-D