CALIBRATE THE SENSORS
FUEL LEVEL SENSOR
•
Connect the sensor of interest. See "Connecting an analogue sensor".
•
Under Sensors select the resistive or voltage depending input to which the sensor is connected.
•
Under Fuel > Sensor, choose the desired configuration.
•
If you have chosen the CUSTOM configuration, follow the wizard on the display to create the sensor
curve. (You will have to fill your tank to a certain level and then confirm the current sensor value and
repeat that for several points of the curve)
•
Under Sensors select the resistive or voltage depending input of step 2.
•
Under Fuel > Tank no., select the ID to be assigned to the tank to which the sensor is connected.
FRESH WATER LEVEL SENSOR
•
Connect the sensor of interest. See "Connecting an analogue sensor".
•
Under Sensors select the resistive or voltage depending input to which the sensor is connected.
•
In Fresh water > Sensor choose the desired configuration.
•
If you have chosen the CUSTOM configuration, follow the wizard on the display to create the sensor
curve. (You will have to fill your tank to a certain level and then confirm the current sensor value and
repeat that for several points of the curve)
•
Under Sensors select the resistive or voltage depending input of step 2.
•
Under Fresh water > Tank no., select the ID to be assigned to the tank to which the sensor is
connected.
WASTEWATER LEVEL SENSOR
•
Connect the sensor of interest. See "Connecting an analogue sensor".
•
Under Sensors select the resistive or voltage depending input to which the sensor is connected.
•
In WASTE > Sensor choose the desired configuration.
•
If you have chosen the CUSTOM configuration, follow the wizard on the display to create the sensor
curve. (You will have to fill your tank to a certain level and then confirm the current sensor value and
repeat that for several points of the curve)
•
Under Sensors select the resistive or voltage depending input of step 2.
•
Under Fresh water > Tank no., select the ID to be assigned to the tank to which the sensor is
connected.
RUDDER ANGLE SENSOR
•
Connect the sensor of interest. See "Connecting an analogue sensor".
•
Under Sensors select the resistive or voltage depending input to which the sensor is connected.
•
In Rudder choose the desired configuration type.
•
If you have chosen the CUSTOM configuration, follow the wizard on the display to create the sensor
curve. (You will have to bring the rudder to a certain position and then confirm the current sensor value
and repeat that for several points of the curve)
21
SENSOR CONFIGURATION