CALIBRATE THE SENSORS

FUEL LEVEL SENSOR
Connect the sensor of interest. See "Connecting an analogue sensor".
Under Sensors select the resistive or voltage depending input to which the sensor is connected.
Under Fuel > Sensor, choose the desired configuration.
If you have chosen the CUSTOM configuration, follow the wizard on the display to create the sensor
curve. (You will have to fill your tank to a certain level and then confirm the current sensor value and
repeat that for several points of the curve)
Under Sensors select the resistive or voltage depending input of step 2.
Under Fuel > Tank no., select the ID to be assigned to the tank to which the sensor is connected.
FRESH WATER LEVEL SENSOR
Connect the sensor of interest. See "Connecting an analogue sensor".
Under Sensors select the resistive or voltage depending input to which the sensor is connected.
In Fresh water > Sensor choose the desired configuration.
If you have chosen the CUSTOM configuration, follow the wizard on the display to create the sensor
curve. (You will have to fill your tank to a certain level and then confirm the current sensor value and
repeat that for several points of the curve)
Under Sensors select the resistive or voltage depending input of step 2.
Under Fresh water > Tank no., select the ID to be assigned to the tank to which the sensor is
connected.
WASTEWATER LEVEL SENSOR
Connect the sensor of interest. See "Connecting an analogue sensor".
Under Sensors select the resistive or voltage depending input to which the sensor is connected.
In WASTE > Sensor choose the desired configuration.
If you have chosen the CUSTOM configuration, follow the wizard on the display to create the sensor
curve. (You will have to fill your tank to a certain level and then confirm the current sensor value and
repeat that for several points of the curve)
Under Sensors select the resistive or voltage depending input of step 2.
Under Fresh water > Tank no., select the ID to be assigned to the tank to which the sensor is
connected.
RUDDER ANGLE SENSOR
Connect the sensor of interest. See "Connecting an analogue sensor".
Under Sensors select the resistive or voltage depending input to which the sensor is connected.
In Rudder choose the desired configuration type.
If you have chosen the CUSTOM configuration, follow the wizard on the display to create the sensor
curve. (You will have to bring the rudder to a certain position and then confirm the current sensor value
and repeat that for several points of the curve)