Pulse Trigger - Rigol DS6062-DEMO User Manual

Digital oscilloscope
Hide thumbs Also See for DS6062-DEMO:
Table of Contents

Advertisement

RIGOL

Pulse Trigger

Trigger on positive or negative pulse with specified width.
Trigger Type:
Press Type to select "Pulse". At this point, the trigger setting information as shown in
the figure below is displayed at the upper right corner of the screen.
Source Selection:
Press Source to select CH1-CH4 or EXT as the Trigger Source. The current trigger
source is displayed at the upper right corner of the screen.
Pulse Condition:
Press When to select the desired pulse condition.
: trigger when the positive pulse width of the input signal is greater than
the specified Pulse Width Setting.
: trigger when the positive pulse width of the input signal is lower than the
specified Pulse Width Setting.
: trigger when the positive pulse width of the input signal is greater than
the specified Lower Limit of Pulse Width and lower than the Upper Limit of
Pulse Width.
: trigger when the negative pulse width of the input signal is greater than
the specified Pulse Width Setting.
: trigger when the negative pulse width of the input signal is lower than
the specified Pulse Width Setting.
: trigger when the negative pulse width of the input signal is greater than
the specified Lower Limit of Pulse Width and lower than the Upper Limit of
Pulse Width.
Pulse Width Setting:
In this oscilloscope, positive pulse width is defined as the time difference between
the two crossing points of trigger level and positive pulse. As shown in the figure
below: