AIR COOLING INTERFACES

Cooling air baffle
Figure 8.5: Cooling air baffle position, TYPICAL
Position
P1
General
NOTE
information
In some special cases a separate cold air supply to the air baffle should be
provided.
Cylinder wall
Max. permitted cylinder wall temperature on hottest cylinder is 200 °C (392 °F). See the
temperature
following figure. The cylinder wall temperature can be measured using a thermocouple.
NOTE
If this temperature is exceeded, appropriate measures (e.g. cooling air ducts,
modifications to cowling, etc.) must be taken to bring it within limits again.
Effectivity: 916 i A / C24
Edition 0/Rev. 1
BRP-Rotax
INSTALLATION MANUAL
x-axis
- 142 mm (- 5.59 in.)
y-axis
- 101 mm (- 3.98 in.)
z-axis
- 106 mm (- 4.17 in.)
75–00–00
Page 7
December 01 2023