Communication Port (Management and Communication Options)
Select Communication Port to configure the unit's COM port.
Communication Port
Configuration Option
Port Use
When Port Use is set to Terminal:
Data Rate (Kbps)
Character Length
Parity
Stop Bits
Ignore Control Leads
Login Required
Port Access Level
Inactivity Timeout
Disconnect Time (Minutes)
When Port Use is set to Net Link:
Data Rate (Kbps)
Character Length
Parity
Stop Bits
Ignore Control Leads
IP Address
Subnet Mask
RIP
External Modem (Management and Communication Options)
Select External Modem (on Com Port) to configure the communications port when it is
connected to an external device like an external modem.
External Modem (on Com Port)
Configuration Option
External Modem Commands
Dial-In Access
Settings
[Terminal], Net Link
9.6, 14.4, [19.2], 28.8, 38.4, 57.6, 115.2
7, [8]
[None], Even, Odd
[1], 2
[Disable], DTR
Enable, [Disable]
[Level-1], Level-2, Level-3
[Enable], Disable
1–60
[10]
9.6, 14.4, [19.2], 28.8, 38.4, 57.6, 115.2
7, [8]
[None], Even, Odd
[1], 2
[Disable], DTR
001.000.000.000–223.255.255.255, [Clear]
[000.000.000.000]–255.255.255.255, Clear
[None], Standard_out
Settings
[Disable], AT
[Enable], Disable
19
Default in [Bold]
Default in [Bold]