Minimal Configuration

The following procedure is a guide to the configuration options modified during typical
installations. To determine whether you need to change particular configuration options
from their default values, see
the options, see the User's Guide.
Procedure
1. Select the Configuration menu.
Main Menu
2. Select the Network menu. Verify that the following are suitable for your network:
— Line Framing Format (default is ESF)
— Line Coding Format (default is B8ZS)
— Line Build-Out (default is 0.0)
3. Press the Escape key to return to the Configuration Edit/Display menu.
4. Select the Management and Communication menu, then select Node IP. Enter the
Node IP Address and Subnet Mask.
5. Press the Escape key to return to the Configuration Edit/Display menu.
6. If the Ethernet port will be used, select the Ethernet Port Options Screen, and
configure the following:
— Enable Interface Status. If the NMS will be on a different subnet than the unit,
enter Yes at the Would you like to set the Node's Default IP
Destination to Ethernet? prompt. Otherwise, enter No.
— If the IP Address and Subnet Mask are unique to the interface, enter them for
the port; otherwise, the Node IP Address and Subnet Mask (found on the
Node IP configuration options screen) will be used.
— Enter the Default Gateway Address; the IP Address that will be used for
packets without a route.
7. Press the Escape key twice to return to the Configuration Edit/Display menu.
8. Select the Time Slot Assignment menu, then select Sync Data Port Assignments.
Assign the user data port to network interface time slots.
9. Press Ctrl-a, s, and Enter to Save the configuration.
The 7123 DSU/CSU installation is complete.
Configuration Options
Configuration
on page 15. For a full description of