Save Current Configuration - 0x62
This command saves a backup copy of the current configuration to nonvolatile memory in the
VC4™ monitor. This configuration can be restored using the Restore Configuration command.
Command packet to instrument:
          Command Code (0x62) - 1 byte
Response packet from instrument:
          Command Code (0x62) - 1 byte
VC4™ Date - 2 bytes
VC4™ Time - 2 bytes
          Status - 1 byte
                    0x00 = Configuration saved
                    0xff = Error
Restore Configuration - 0x63
This command restores a configuration that was previously saved to nonvolatile memory in the
CM4 monitor.
Command packet to instrument:
          Command Code (0x63) - 1 byte
Response packet from instrument:
          Command Code (0x63) - 1 byte
VC4™ Date - 2 bytes
VC4™ Time - 2 bytes
          Status - 1 byte
                    0x00 = Configuration restored
                    0xff = Error, configuration unchanged