Image 7–26 Example of the RealColor P7 menu, here on a UDX
2.
Select the desired Custom Mode. Select one of the following Custom options and confirm:
Custom RGB: 3–point color configuration.
In RGB mode, the C, M and Y coordinates will be calculated automatically based on the R, G and B
coordinates.
Custom RGBCMY: 6–point color configuration (both RGB and CMY).
In RGBCMY mode, each color can be given a specific coordinate within the measured color triangle.
Custom WHITE: Configure only the White temperature.
3.
Choose how to determine the Whitepoint. Choose one of the following:
Coordinates: Configure the white point via specific coordinates.
The white point is specified using an x, y coordinate in the CIE 1931 Chart.
Temperature: Configure the white point via a color temperature slider.
The white point is specified on a Kelvin scale between 3200K and 13000K tracking along the black
body curve.
4.
Define the coordinates for each available color.
Click on a coordinate value and select the current value. Enter the desired value with the numeric keys.
Note: You can only pick coordinates within the measured color triangle.
You can reset all coordinates to the default values (to native) by clicking the Reset icon.
How to choose one of the P7 presets
1.
In the main menu, select Image → Advanced → P7 Realcolor.
Image 7–27 Advanced settings menu – RealColor P7
The P7 menu is displayed.
GUI – Image