Miele PDR 914 Operating And Installation Instructions page 67

Commercial tumble dryers
Hide thumbs Also See for PDR 914:
Table of Contents

Advertisement

Gas regulator valve
Cap
Nut
Jet pressure adjust-
ment
Setting maximum
pressure at full
heating
Adjusting the mini-
mum pressure with
power supply inter-
rupted
Electrical plug
Make sure that the maximum pressure is set first. Else the mini-
mum pressure would be changed by turning the nut.
Loosen the locking bolts of the connection pressure and jet pressure
measuring stub.
Check the connection pressure and jet pressure.
Remove the cap from the pressure regulator.
Fit a socket wrench or a ringspanner to the nut of the pressure regu-
lator.
Values for natural gas: see table "Settings with natural gas"; values
for liquid gas: see table "Settings with liquid propane"
To increase or reduce the maximum jet pressure turn the nut in a
clockwise or counterclockwise direction.
Pull out the plug. You need a slotted Screwdriver to adjust the mini-
mum pressure.
To increase or reduce the minimum jet pressure turn the slotted
screw inside the nut in a clockwise or counterclockwise direction.
Make sure that the nut does not turn with it.
Insert the plug again.
Fit the cap onto the pressure regulator.
Seal the connection pressure and jet pressure measuring stubs with
the locking bolts.
Connection pressure
measuring stub
Pressure regulator
Installation
67