Revision History Rev. Details Initial Release Added description of what other features are affected when Passage Mode is enabled. Fixed Minimum value for Auto Relock Time and fixed Default Value for Auto Relock Feature...
Yale Z-Wave Plus ™ Product Info Manufacturer ID: ASSA ABLOY (0x0129) Z-Wave™ Device Type: Door Lock Keypad Z-Wave™ Role Type: Listening Sleeping Slave (LSS) Network Operations Enroll/Add device to network (SmartStart) SmartStart enabled products can be added into a Z-Wave™ network by scanning the Z-Wave™...
When the Yale lock is unenrolled/excluded from the network through the device menu mode, any changes previously made to the user code database and configuration settings will be retained, as opposed to set back to defaults. Factory Reset • Factory resetting the lock with the Z-Wave™ module installed will clear the Z-Wave™...
* This command class requires security. The Manufacturer Specific command class reports the following information: • Manufacturer ID: 0x0129 o This is the manufacturer ID assigned to ASSA ABLOY. • Product ID: o The Product ID can be used to differentiate between hardware platforms, as well as between ZW2 and ZW3.
Command Class Device Reset Locally, Version 1* * This command class requires security. The Yale door locks covered in this guide can be reset to their factory default settings by manually resetting the lock by following the procedure outlined in the specific lock’s manual.
After a controller sends a Version Get command the log will display the Version Report similar to the below: The above Version Report will be defined as this in the Z-Wave™ sniffer tool, Zniffer: For Firmware Target 0, the Firmware 0 Version (0x02) and Sub version (0x22) translate to module firmware decimal value of “2.34”.
Command Class Door Lock, Version 4* * This command class requires security. Yale Z-Wave Plus ™ locks support three door lock modes: Door Secured (0xFF), Door Unsecured (0x00), and Door Unsecured with timeout (0x01). When Auto Relock is enabled, the lock will automatically relock after all unlock events. Yale Z- Wave Plus ™...
Page 11
Table 2 – Expected Reports for Set/Get Commands Slots 256- Command Slots 1-250 Slot 251 Slots 252-254 Slot 255 User Code CC User Code User Code User Code v1/v2: User User Code Report Report Report Report Code Get User Code CC Master User Code User Code...
Page 12
Table 3 - User ID Status User Code CC v1 vs v2 User ID Status User Code CC v1 Set User Code CC v1 Report Value Description Value Value Available 0x00 0x00 Enabled / Grant Access 0x01 0x01 0x02 Disabled 0x03 0x03 Messaging:...
Page 13
User ID User Code CC v2: Extended User Code CC v2: Extended User Status User Code Set Code Report Value Description Value Value Available 0x00 0x00 Enabled / 0x01 0x01 Grant Access Disabled 0x02 0x02 Messaging: The user code is accepted, but the lock does not grant access to the...
Command Class Time Parameters, Version 1* * This command class requires security. The controller must set the Time Parameters in the lock anytime the lock loses power. If the time is not set by the controller, then user codes with schedules applied to them cannot be granted access.
Firmware Target 0 is used to determine the correct Z-Wave™ processor image to download. ID 1 is always 0xA5, to signal this is an ASSA ABLOY Z-Wave™ image, and ID 2 is specific to the region, with the lower nibble being 0x0 and the upper nibble being the value in Table 4 - Region-Specific Values for Firmware ID 0.
• For Z-Wave™ Radio Chip, ~10 seconds • For NTT612/622-ZW3 (2nd Generation Exit Trim lock), ~23 minutes Command Class Association, Version 2* * This command class requires security. This command class has been implemented per the Z-Wave™ Specification. Command Class Multi Channel Association, Version 3* * This command class requires security.
Command Class Association Group Info, Version 3* * Command Class Requires Security Yale locks support the Lifeline Association Group. Table 5 - Association Table Group ID Maximum Nodes Description Commands • Command_Class Battery Battery_Report • Command_Class_Configuration Configuration_Report • Command_Class_Notification Notification_Report •...
Page 18
The following are the actions to trigger the reports: Table 6 – Lifeline Report Trigger Table Report Command RF Trigger Manual Trigger Battery Report Any RF Lock Operation when lock is Any manual/keypad Lock Operation under the battery thresholds when lock is under the battery thresholds or Power Cycle Lock Configuration Report Configuration Set...
Command Class Notification, Version 8* * This command class requires security. Table 7 - Notification Table Alarm Alarm Notification Alarm Reports Description Event type Level Type 0x (01 – Keypad Lock 0x12 Where Alarm level represents user slot number 0x06 0x05 max users) 0x(01-max...
Page 20
0X0D 0x(01-max User was deleted. Alarm level = user slot (single) users) number User deleted 0x21 0x06 0X0C 0x00 All User codes were deleted (all) 0x(01-max A Non-Access Code was entered at the lock. Non-Access 0x26 0x06 0xFE users) Where alarm level represents user slot number 0x00 Door is open 0x06...
Page 21
All Schedule Types 0x(01-max Schedule(s) has been enable/disabled for 0x65 0x06 0xFE Enabled/Disabled users) specified user ID 0x00 Master code was changed at keypad 0x06 0x12 Master Code changed 0x00 Master code was changed over RF 0x06 0x0E 0x70 0x(01-max User added User added.
Command Class Configuration, Version 4* * This command class requires security. Table 8 - Configurable Parameters Length of Info Configuration Properties Info String (max length Param. allowed Num. Name Length Default is 90) 0x01 (High 0x03 0x01 (High Set Volume Level to high (1), Volume 1 byte Volume)
Page 23
Set the language to English 0x01 0x03 0x01 (1), Spanish (2), or French Language 1 byte (English) (French) (English) (3). Adjust the time your lock is Shut down 0x0A (10 0x84 (132 0x3C (60 shutdown after reaching its time 1 byte seconds) seconds) seconds)
Page 24
Expiring Pin Timeout value used to Code 0x00 0xFF (127 0x00 1 byte determine time after first Enabled (Disable) Hours) (Disable) entry is triggered. Time ¹ Even know we accept value 0x01 for Auto Relock Time, we limit the lock’s minimum to value of 0x03. Therefore, if user tries to set Auto Relock Time to values 0x01 or 0x02 , it will always report back value of 0x03.
Command Class Application Status, Version 1 This command class has been implemented per the Z-Wave™ Specification. Command Class Transport Service, Version 2 This command class has been implemented per the Z-Wave™ Specification. Command Class Supervision, Version 1 This command class has been implemented per the Z-Wave™ Specification. Command Class Indicator, Version 3* * This command class requires security.
Page 26
Command Class Basic, Version 2* * This command class requires security. This command class is mapped to Door Lock CC: Table 11 – Basic Mapping Overview Basic Command Door Lock Mapped Command Basic Set (Value) Door Lock Operation Set (Door Lock Mode) Basic Report (Current Value = 0x00) Door Lock Operation Report (Door Lock...