Page 1
CoreSight Galvanic Isolation Adapter Hardware User Manual V1.3, November 2023 isystem.com/start...
Page 2
General safety instructions Please read the following safety precautions carefully before putting this device to use to avoid any personal injuries, damage to the instrument, or to the target system. Use this instrument only for its intended purpose as specified by this manual to prevent potential hazards. Use included power cord and power supply The enclosed power supply has been approved for use by iSYSTEM.
Introduction Galvanic isolation is used where two electric circuits must communicate, but their grounds may be at different potentials. It is an effective method of breaking ground loops between the two cir- cuits. Galvanic isolation is also used for safety, preventing accidental current from reaching ground through a person's body.
Package content CoreSight 20-pin 1.27 mm Galvanic Isolation Adapter is delivered with the following compon- ents: CoreSight 20-pin 1.27 mm USB PD Power supply Ribbon cable Galvanic Isolation Adapter Ordering code: Ordering code: Ordering code: IEA-GI-CORESIGHT IT5V2AUSBC-PS IA20PIN20_10PIN-CS...
Specifications GENERAL Operating temperature 10°C to 40°C Storage temperature -10°C to 60°C MECHANICAL Size 65 x 40 x 19 mm Weight approx. 55 g ELECTRICAL Isolation Type Basic Isolation Ratings 1 kVrms VIORM * 560 V peak DEBUG TOOL SIDE Supply Voltage 5 V (via attached power supply) Max Supply Current...
Device overview A – DEBUG TOOL connector. B – TARGET connector. C – LED lights indicate power supply status. If LEDs on the GI Adapter are OFF, immediately turn everything OFF! D – USB PD Power supply socket (PWR). Use only original USB PD Power supply for powering and connecting with the GI Ad- apter, otherwise the primary functionality of the GI Adapter would be counteracted.
Page 9
Pinout 10-pin 1.27 mm CoreSight Debug Adapter The following pinout is valid on the target side: Signal Dir- Signal Dir- Signal Description Signal Signal Signal Description ection ection Reference Voltage Vref SWDIO/TMS SWD/JTAG I/O / O Ground SWCLK/TCK SWD/JTAG Ground SWO/TDO SWD/JTAG Not Connected...
Connecting procedure Do not use a Grounding wire between the BlueBox and the embedded target since it would counteract the primary functionality of the Galvanic Isolation (GI) Adapter! 1. Make sure you select a suitable debug interface (SWD, JTAG) via switches SW1 and SW2 on the GI Adapter.
Accessories Ordering Code Description IC57000 iC5700 BlueBox IC50118-2 20-pin 1.27 mm CoreSight Debug Adapter More information about our products on www.isystem.com or via sales@isystem.com.
Page 12
Visit our website for: · Support - isystem.com/support · Tutorials - isystem.com/start · Knowledge Base - kb.isystem.com www.isystem.com...