4-21. Timer/Cycle Counter
1
1
1
Amperage Control
2
Output Control (Contactor)
To read timer/cycle counter, hold Amper-
age and Output (contactor) buttons while
turning on power.
Syncrowave 250 DX
2
(CE Nameplate)
2
3
Timer Display
The hours and minutes are displayed on
the volt and amp meters for the first five
seconds, and are read as 1, 234 hours
and 56 minutes.
1 2 3
4 5 6
1 2 3
4 5 6
4
Cycle Display
The cycles are displayed on the volt and
amp meters for the next five seconds,
and are read as 123, 456 cycles.
TM-359 Page 51
3
4