Receptacle
Pin
14
RC4
1
2
3
4
5
6
RC5
1
2
RC6
1
2
3
4
5
6
7
8
RC7
1
2
RC8 (Prior to
1
LC451816)
2
3
4
5
6
7
8
9
10
RC9
1
2
3
4
5
6
7
TM-359 Page 72
Not used
Output Selector switch S5 position sense signal, 0 volts DC while in AC or DCEN positions, +5 volts
DC while in DCEP position
Output Selector switch S5 position sense signal, 0 volts DC while in AC or DCEP positions, +5 volts
DC while in DCEN position
Output Selector switch S5 position sense ground reference
Voltage feedback sense lead−work
Voltage feedback sense lead−electrode
Background voltage negative, -98 volts dc
Thermistor input from rectifier, +5 volts dc
+5 volts DC from thermistor
+24 volts DC output
Contactor, +24 volts DC with external output control closed
Remote Amperage control reference +10 volts dc
Ground reference for Remote Amperage control
Remote Amperage control input 0 to +10 volts dc
Output current feedback, +1 volt dc per 100 amperes
Ground reference for +24 volts dc
Output voltage feedback, +1 volt dc per 10 volts output
Thermistor input from stabilizer, +5 to 0 volts dc
+5 volts DC for stabilizer thermistor
Pulse lockout − collector, see output below
Final slope − emitter, 0 to +30 volts DC depending on collector voltage
Final slope − collector, see output below
Valid arc − emitter, 0 to +30 volts DC depending on collector voltage
Valid arc − collector, see output below
Pulse lockout − emitter, 0 to +30 volts DC depending on collector voltage
Start/stop, 0 volts DC while on, +5 volts DC while off
Gas valve, 0 volts DC while on
Output enable, 0 volts DC while on, +5 volts DC while off
Ground reference for chassis
OUTPUTS
User supplied signal, 0 to +30 volts DC and 6 to 100 mA
Background voltage positive, +98 volts dc
Ground reference for chassis
115 volts AC for high frequency
High frequency control, 115 volts AC when on, 0 volts AC when off
Ground reference for 19 volts AC winding
19 volts AC input from transformer T1
19 volts AC input from transformer T1
Value
Syncrowave 250 DX