Urinal water pipe section for urinals with concealed flushing system, urinal flush plates for prevista (manual and touchless flush actuation) (13 pages)
Summary of Contents for Viega Prevista Dry 8535.31
Page 1
Instructions for Use Prevista Dry washbasin element 820 – 980 mm for WB with single-hole fitting Model Year built (from) 8535.31 09/2018...
Table of contents Table of contents About these instructions for use 1.1 Target groups 1.2 Labelling of notes 1.3 About this translated version Product information 2.1 Standards and regulations 2.2 Intended use 2.2.1 Areas of application 2.3 Product description 2.3.1 Overview 2.3.2 Compatible components...
This restriction does not extend to possible operating instructions. The installation of Viega products must take place in accordance with the general rules of engineering and the Viega instructions for use.
About these instructions for use About this translated version This instruction for use contains important information about the choice of product or system, assembly and commissioning as well as intended use and, if required, maintenance measures. The information about the products, their properties and application technology are based on the current standards in Europe (e.g.
Product information Product information Standards and regulations The following standards and regulations apply to Germany / Europe and are provided as a support feature. Regulations from section: Fields of application / Mounting conditions Scope / Notice Regulations applicable in Ger‐ many Suitable masonry walls EN 1996-1-1...
Product information Product description 2.3.1 Overview Fig. 1: Components and scope of delivery Washbasin element Mounting bracket for drain elbow Drain elbow Screws and dowels for fixing in the floor Screws for fixing in stud frame Assembly accessories wall plates Protective plug Flushing pipe connector Threaded rods for fixing sanitary objects...
Product information 2.3.3 Technical data Drain elbow (outlet side) DN 40 / 50 Rubber nipple DN 50 / 30 Hole diameter for fixing in wooden 11 mm frame construction Construction height 820 — 980 mm Prevista Dry washbasin element 820 – 980 mm...
Product information Accessories For mounting, Viega recommends to use the Prevista Dry fixing set. Prevista Dry fixing set model8570.36 for fixing the Prevista Dry elements in single / line mounting, single mounting directly onto the installation body or corner mounting on masonry or steel stud frame.
Handling Handling Assembly information 3.1.1 Mounting conditions Suitable walls Masonry walls Concreted walls Steel stud frame Prevista Dry Plus pre-wall constructions The wall constructions must comply with the regulations in section Ä ‘Regulations from section: Fields of application / Mounting conditions’ on page 5.
Mounting the element Masonry and concrete walls When mounting multiple washbasin elements with an interval of > 500 mm, Viega recommends to use a Pre‐ vista Dry support bracket (model 8570.48). Observe the instructions for use of the support bracket when mounting.
Page 11
Handling Mounting to a masonry or concrete wall For mounting, Viega recommends to use a Prevista Dry fixing set. ▶ Determine and mark the fixing points. X1 with construction height 820: 800 mm X1 with construction height 980: 960 mm X2: Depending on the fixing set used ▶...
Page 12
Handling ▶ Adjust the construction height of the element in accordance with the on-site marking of the upper edge of the finished floor. X with construction height 820: 800 mm X with construction height 980: 960 mm ▶ Tighten the feet of the element using a fork spanner. ▷...
Page 13
Handling Mounting in Prevista Dry Plus NOTICE! When mounting without a continuous rail above the ele‐ ment, the Prevista Dry Plus fixing set (model 8570.49) must also be used. See example with WC element model 8521. Mount the Prevista Dry Plus pre-wall construction pur‐ suant to the instructions for use of the Prevista Dry Plus system.
Page 14
Handling ▶ Fix the element with the Prevista Dry Plus rail connectors. ▷ The element is fixed in the Prevista Dry Plus pre-wall construc‐ tion. Prevista Dry washbasin element 820 – 980 mm...
Page 15
Handling Mounting in steel stud frame ▶ Position the element on the floor rail. ▶ If necessary, adjust the foot depth from 50 mm (pre-mounted) to 75 ▶ Pull the foot out and turn by 90°. ▶ Fix the feet. ▶...
Handling 3.2.2 Set and clad the element ▶ Use the quick release to adjust the drain elbow to the desired height. Observe the instructions of the sanitary objects manufacturer. ▶ Set the ledges to the desired height. ▶ Mount the drain elbow. Prevista Dry washbasin element 820 –...
Page 17
Handling ▶ Mount the seal and the plug. ▶ Turn in the threaded rods by hand. ▶ Tighten the nuts of the threaded rods with a fork spanner. ▶ Place the protective caps on the threaded rods. ▶ Make the water connections. ▶...
Handling ▶ Cut out the recesses for the plug and the threaded rods. X1: min. 58 mm ▶ Clad the element with suitable plasterboard cladding panels. Disposal Separate the product and packaging materials (e. g. paper, metal, plastic or non-ferrous metals) and dispose of in accordance with valid national legal requirements.
Page 19
Viega GmbH & Co. KG service-technik@viega.de viega.com INT • 2023-01 • VPN210809...