Page 1
Prevista Pure urinal water pipe section Instructions for Use for urinals with concealed flushing system, urinal flush plates for Prevista (manual and touchless flush actuation) Model Year built: 8566 from 06/2019 en_INT...
Page 2
Prevista Pure urinal water pipe section 2 from 13...
Table of contents Table of contents About these instructions for use Target groups Labelling of notes About this translated version Product information Standards and regulations Intended use 2.2.1 Areas of use Product description 2.3.1 Overview 2.3.2 Technical data Handling Assembly information 3.1.1 Mounting conditions 3.1.2...
This restriction does not extend to possible operating instructions. The installation of Viega products must take place in accordance with the general rules of engineering and the Viega instructions for use.
About these instructions for use About this translated version This instruction for use contains important information about the choice of product or system, assembly and commissioning as well as intended use and, if required, maintenance measures. The information about the products, their properties and application technology are based on the current standards in Europe (e.g.
Product information 2 Product information Standards and regulations The following standards and regulations apply to Germany / Europe and are provided as a support feature. Regulations from section: Technical data Scope / Notice Regulations applicable in Ger‐ many Flush flow DIN 3265 Noise class DIN 4109...
Handling 3 Handling Assembly information 3.1.1 Mounting conditions Installation dimensions Fig. 1: Installation dimensions in accordance with manufacturer's documentation urinal ceramic B in accordance with manufacturer's documentation urinal ceramic C in accordance with manufacturer's documentation urinal ceramic D in accordance with manufacturer's documentation urinal ceramic in accordance with manufacturer's documentation urinal ceramic upper edge of the finished floor min.
Handling Location diagram for power pack, terminals, battery and control. 3.1.2 Installation dimensions Fig. 2: Dimensional drawing Prevista Pure urinal water pipe section 9 from 13...
Handling Assembly 3.2.1 Assembly DANGER! Danger due to electrical current An electric shock can lead to burns and serious injury and even death. – Work on the electrics may only be carried out by trained electricians. – Switch off the mains voltage before carrying out work on electrical parts.
Page 11
Handling Remove the site protection. Fasten the urinal water pipe section to the wall. Connect the water pipeline to the urinal water pipe section inlet. Install the water pipeline from the urinal water pipe section up to the sanitary object. Prevista Pure urinal water pipe section 11 from 13...
Page 12
Handling INFO! Connect a maximum of three elbows. DANGER! Risk of electric shock. An electric shock can lead to burns and serious injury and even death. – Only allow electrical work to be carried out by qualified elec‐ tricians. – Always de-energise the connection cable before work is com‐ menced.
Handling Wall in the urinal water pipe section. INFO! Observe the maximum plaster thickness. Plaster the urinal water pipe section and tile. Disposal Separate the product and packaging materials (e. g. paper, metal, plastic or non-ferrous metals) and dispose of in accordance with valid national legal requirements.
Need help?
Do you have a question about the Prevista Pure 8566 and is the answer not in the manual?
Questions and answers