Prevista Dry Plus washbasin module, bar‐ rier-free Instructions for Use for WB with single-hole fitting Model Year built: 8545.31 from 03/2019 en_INT...
Page 2
Prevista Dry Plus washbasin module, barrier-free 2 from 11...
Table of contents Table of contents About these instructions for use Target groups Labelling of notes About this translated version Product information Intended use 2.1.1 Areas of use Product description 2.2.1 Overview 2.2.2 Compatible components Handling Assembly information 3.1.1 Mounting conditions 3.1.2 Installation dimensions Assembly...
This restriction does not extend to possible operating instructions. The installation of Viega products must take place in accordance with the general rules of engineering and the Viega instructions for use.
About these instructions for use About this translated version This instruction for use contains important information about the choice of product or system, assembly and commissioning as well as intended use and, if required, maintenance measures. The information about the products, their properties and application technology are based on the current standards in Europe (e.g.
Product information 2 Product information Intended use 2.1.1 Areas of use The Prevista Dry Plus washbasin module is designed for mounting in a Prevista Dry Plus pre-wall construction. Product description 2.2.1 Overview Fig. 1: Components and scope of delivery Washbasin module Wall bracket for concealed odour trap Screws for fixing in support profile Assembly accessories concealed odour trap...
Handling 3 Handling Assembly information 3.1.1 Mounting conditions Suitable walls Prevista Dry Plus pre-wall constructions The washbasin module may only be mounted on even wall surfaces. Construction height With the construction height, the marked height of the upper edge of the finished floor must be observed.
Page 8
Handling The two vertical rails, which surround the module, must be open towards the module and have an inner distance of 420 mm. Secure the module onto the open mounting rail with the slot nuts supplied. Insert the slot nut into the opening of the module. Push the slot nut in until it engages.
Page 9
Handling Fasten the slot nut. 25 Nm Bend the sides of the metal bars of the rails. Bend the sides of the metal bars of the fitting holder. Set the height of the module according to the ceramic manufactur‐ er's instructions. Prevista Dry Plus washbasin module, barrier-free 9 from 11...
Handling 3.2.2 Set and clad the module Mount an odour trap. Turn in the threaded rods by hand. Tighten the nuts of the threaded rods with a fork spanner (size 17). Place the protective caps on the threaded rods. Make the water connections. Cut the gypsum cardboard cladding panel to size.
Handling Clad the module with suitable gypsum cardboard cladding panels. Disposal Separate the product and packaging materials (e. g. paper, metal, plastic or non-ferrous metals) and dispose of in accordance with valid national legal requirements. Prevista Dry Plus washbasin module, barrier-free 11 from 11...