Fronius TransPocket 1100 Operating Instructions Manual page 39

Table of Contents

Advertisement

Available languages

Available languages

Particular danger
spots
(continued)
Factors affecting
welding results
Risk of scalding from accidental discharge of hot coolant. Before unplugging
the connectors for coolant forward flow and return flow, switch off the coo-
ling unit.
Observe the information on the coolant safety data sheet when handling
coolant. The coolant safety data sheet may be obtained from your service
centre or downloaded from the manufacturer's website.
When hoisting the machines by crane, only use suitable manufacturer-
supplied lifting devices.
-
Attach the chains and/or ropes to all the hoisting points provided on the
suitable lifting device.
-
The chains and/or ropes must be at an angle which is as close to the
vertical as possible.
-
Remove the gas cylinder and the wirefeed unit (from MIG/MAG and TIG
units).
When hoisting the wirefeed unit by crane during welding, always use a
suitable, insulating suspension arrangement (MIG/MAG and TIG units).
If a machine is fitted with a carrying strap or carrying handle, remember that
this strap is ONLY to be used for lifting and carrying the machine by hand.
The carrying strap is NOT suitable for transporting the machine by crane,
fork-lift truck or by any other mechanical hoisting device.
All lifting accessories (straps, handles, chains, etc.) used in connection with
the device or its components must be tested regularly (e.g. for mechanical
damage, corrosion or changes caused by other environmental factors).
The testing interval and scope of testing must comply with applicable natio-
nal standards and directives as a minimum.
Danger of colourless and odourless inert gas escaping unnoticed, when
using an adapter for the inert gas protection. Seal the adapter thread for the
inert gas connection using Teflon tape before assembly.
The following requirements with regard to shielding gas quality must be met
if the welding system is to operate in a correct and safe manner:
-
Size of solid matter particles <40µm
-
Pressure dew point <-20°C
-
Max. oil content <25mg/m³
Filters must be used if necessary.
NOTE! There is an increased risk of soiling if ring mains are being
used
IX
ud_fr_st_sv_00467
022013

Advertisement

Table of Contents
loading

This manual is also suitable for:

Transpocket 1200

Table of Contents