WEG CFW11 Applications Manual page 7

Solar pump drive
Hide thumbs Also See for CFW11:

Advertisement

Quick Parameter Reference, Faults and Alarms
Parameter
Description
P1001
Command for SoftPLC
Solar Pump Drive Application
P1010
Version
P1011
Current Tracking Setpoint
Actual Pressure Setpoint /
P1012
Speed
P1013
Pressure Reading
P1014
Running Time
P1015
Total Energy
Remaining Time to a new Start
P1016
Attempt
P1017
Deviation Stopping Value of AI2 0.0 to 100.0 %
P1018
DC Link Voltage Filter
P1019
Increment Rate MPPT
P1022
Minimum Setpoint Vdc
P1023
Maximum Setpoint Vdc
P1024
PID Proportional Gain Vdc
P1025
PID Integral Gain Vdc
P1026
PID Integral Gain Vdc
P1027
Time Between Starts
P1028
Enable Starting Value of AI2
Actuation Value DOx
AI2 Value to Start an External
P1029
Power Source (Network /
Group)
P1030
Pressure Control
P1031
Pressure Sensor Scale
P1032
PID Proportional Gain Pressure
P1033
PID Integral Gain Pressure
P1034
PID Integral Gain Pressure
Motor Speed below which Solar
P1035
Pump Drive goes to Sleep Mode
Time Delay for Solar Pump
P1036
Drive goes to Sleep Mode
Control Process Variable
P1037
Deviation for Solar Pump Drive
to Wake Up
Cloud/Load Controller Activation
P1038
Level
P1039
Cloud/Load Controller Gain
Time Delay for Dry Pump Fault
P1040
(F765)
P1041
Motor Speed for Dry Pump
P1042
Motor Current for Dry Pump
P1043
Time Reset Fault for Dry Pump
P1044
Minimum Output Pressure
P1045
Minimum Fault Pressure Time
P1046
Maximum Output Pressure
P1047
Maximum Fault Pressure Time
P1049
Actuation Time DOx
P1051
Control Setpoint 1 / Manual SP
P1052
Control Setpoint 2
P1053
Control Setpoint 3
P1054
Control Setpoint 4
Running time ((P1014) and
P1059
Total Energy kWh (P1015)
Reset
* Depending on selection of pressure control mode (P1030). If automatic mode is selected, the controlled variable is pressure (mca, psi,
bar, etc). If manual mode is selected, the controlled variable is speed reference (Hz).
Application Default
Adjustable Range
0 to 2
0.00 to 10.00
0 to 1000 V
0.0 to 300.0 (psi/bar/Hz)*
0.0 to 300.0 (psi/bar)
0 to 6553.5 h
0 to 65535 kWh
0 to 3600 s
0.00 a 9.99
10 to 40
0 to 1000 V
0 to 1000 V
0.000 to 32.000
0.00 to 320.00
0.000 to 32.000
0 to 3600 s
0.0 to 100.0 %
0.0 to 100.0 %
0 = Manual
1 = Automatic
2 = DI5 Selection
3 = Disabled
0.0 to 300.0 (psi/bar)
0.000 to 32.000
0.00 to 320.00
0.000 to 32.000
0 to 300.0 Hz
1 to 65000 s
0.0 to 300.0
0.0 a 100.0 %
0.00 a 10.00
0 to 3600 s
0.0 to 300.0 Hz
0.1 to 100.0 %
0 to 720 min
0.0 to 300.0
0 to 3600 s
0.0 to 300.0
0 to 3600 s
0 to 3600 s
0.0 to 300.0 (psi/bar/Hz)*
0.0 to 300.0 (psi/bar)
0.0 to 300.0 (psi/bar)
0.0 to 300.0 (psi/bar)
0 = Not Used
1 = Reset Running Time
2 = Reset Total Energy
User
60 Hz (50 Hz)
Setting
1 = Run Program
-
-
-
-
-
-
-
0.0 %
0.10 s
20
450 V
750 V
1.000
20.00
0.00
60 s
0.0 %
0.0 %
3 = Disable
10.0
1.000
10.00
0.000
0 Hz
10 s
0.0
1.0 %
1.00
0 s
54.0 (45.0) Hz
45.0 %
0 min
0.0
0 s
10.0
0 s
0 s
60.0 (50.0) Hz
1.5
1.5
1.5
0 = Not Used
Prop. Groups
Page
50
-
ro
50
30
ro
50
30
ro
50
30
ro
50
31
ro
50
31
ro
50
31
ro
50
31
50
23
50
-
50
19
50
19
50
19
50
20
50
20
50
20
50
21
50
21
50
23
50
24
50
25
50
25
50
25
50
25
50
26
50
26
50
26
50
21
50
21
50
21
50
21
50
27
50
27
50
27
50
27
50
28
50
28
50
28
50
28
50
23
50
29
50
29
50
29
Solar Pump Drive | 7