Quick Parameter Reference, Faults and Alarms
QUICK PARAMETER REFERENCE
Parameter
Description
P0100
Acceleration Time
P0101
Deceleration Time
P0133
Minimum Speed
P0134
Maximum Speed
P0136
Manual Torque Boost
P0142
Maximum Output Voltage
P0143
Intermediate Output Voltage
P0144
Minimum Output Voltage
P0202
Control Type
P0205
Display Parameter 1
P0206
Display Parameter 2
P0207
Display Parameter 3
P0208
Ref. Eng. Scale Main Display
P0209
Reference Eng. Unit 1
P0210
Reference Eng. Unit 2
P0211
Reference Eng. Unit 3
P0212
Reference Decimal Place
P0220
LOC/REM Selection Source
P0222
REM Reference Sel.
P0226
REM Rotation Selection
P0227
REM Run/Stop Selection
P0228
REM JOG Selection
P0230
Dead Zone (AIs)
P0231
AI1 Signal Function
P0233
AI1 Input Signal
P0235
AI1 Input Filter
P0236
AI2 Signal Function
P0238
AI2 Input Signal
P0251
AO1 Signal Function
P0254
AO2 Signal Function
P0263
DI1 Input Function
P0264
DI2 Input Function
P0265
DI3 Input Function
P0266
DI4 Input Function
P0267
DI5 Input Function
P0268
DI6 Input Function
P0275
DO1 Output Function
P0276
DO2 Output Function
P0277
DO3 Output Function
P0296
Inverter Rated Voltage
P0320
FlyStart/Ride-Through
P0331
Voltage Ramp
P0340
Auto-Reset Time
P0341
Output Voltage Compensation 0 to 1
P0400
Motor Rated Voltage
P0401
Motor Rated Current
P0402
Motor Rated Speed
P0403
Motor Rated Frequency
NOTE!
To load the factory default set parameter P0204 to "7".
Adjustable Range
0.1 to 999.0 s
0.1 to 999.0 s
0 to 18000 rpm
0 to 18000 rpm
0 to 9
0.0 to 100.0 %
0.0 to 100.0 %
0.0 to 100.0 %
0 to 7
2 = Speed in rpm
5 = Frequency in Hz
0 to 40
0 to 40
0 to 65535
72 = H (Hz)
122 = z (Hz)
32 = ' '
0 to 3
0 to 14
0 to 13
0 to 16
0 to 6
0 to 7
0 to 1
6 = Pressure PID
Feedback
0 = 0 to 10 V
1 = 4 to 20 mA
0.00 to 16,00
6 = Solar Sensor Detector
7 = Control Setpoint
0 to 4
12 = Repeat AI1
12 = Repeat AI2
0 to 31
21 = Power by Group or
Network
21 = 1st DI for Control
Setpoint Selection
21 = 2nd DI for Control
Setpoint Selection
21 = Pressure PID
Man/Auto
0 to 31
28 = Triggers External
Power
0 to 8
0 to 3
0.2 to 60.0 s
0 to 3600 s
200 to 600 V
0.0 to 477.0 A
0 to 18000 rpm
0 to 300 Hz
Application Default
User
60 Hz (50 Hz)
Setting
20.0 s
20.0 s
2400 (2000) rpm
3600 (3000) rpm
2
100.0 %
60.0 %
28.0 %
0 (1) = V/F
5 = Output Freq.
4 = DC Link Voltage
3 = Motor Current
600
72 = H (Hz)
122 = z (Hz)
32 = ' '
1 = wxy.z
1 = Always Remote
12= SoftPLC
0 = Clockwise
1 = DIx
0 = Disable
1 = Active
5 = Not Used
0 = 0 to 10 V
0,30 s
5 = Not Used
0 = 0 to 10 V
2 = Real Speed
0 = Speed Reference
1 = Run / Stop
0 = Not Used
0 = Not Used
0 = Not Used
0 = Not Used
0 = Not Used
11 = Run
2 = N > Nx
1 = N* > Nx
According to
inverter model
3 = Ride-Through
10.0 s
0 s
1 = Active
According to
inverter model
60 (50) Hz
Prop.
Groups Page
-
04, 20
-
04, 20
-
04, 22
-
04, 22
-
V/F
04, 23
-
cfg V/F
24
cfg V/F
24
-
-
cfg V/F
24
cfg
05
-
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
cfg
31, 32
-
cfg
32
-
cfg
32
-
cfg
32
-
cfg
32
-
cfg
38
-
cfg
38
24
cfg
38
-
38
-
cfg
38
23
cfg
38
-
cfg
39
24
cfg
39
24
cfg
40
-
cfg
40
24
29
cfg
40
cfg
40
29
cfg
40
25
cfg
40
-
cfg
41
23
cfg
41
23
cfg
41
23
cfg
42
-
cfg
44
-
-
V/f
44
27
45
cfg V/f
-
-
cfg
05, 43
-
cfg
05, 43
-
cfg
05, 43
-
cfg
05, 43