The device is designed for blocking, dosing, filling and ventilating users. gaseous and liquid media. ▶ The liability and warranty for the Type 6026 device will be invali- ▶ When using the device, observe the authorised data, operating dated if the operating instructions are not followed.
Isolation Risk of injury due to electric shock. The device must not be isolated more than ▶ Before reaching into the device or the system, switch off the power 2 cm from the body edge upwards to the supply and secure to prevent reactivation! Observe the applicable accident prevention and safety regulations for electrical devices.
▶ In the case of alternating voltage, pay attention to movable Conformity core. ▶ Check media resistance. The Type 6026 conforms to the EU directives as per the EU Declaration of Conformity (if applicable). General hazardous situations. To prevent injuries, ensure that: Standards ▶...
Media neutral gaseous and liquid media that do not attack the body and seal materials (see resis- Intermittent operation characteristics for variant tance table: www.burkert.com). Check resis- Ambient temperature [°C] with AC/DC high-perfor- tance in each individual case. mance electronics...
Electrical data Mechanical data Connections DIN EN 175301-803 Form A: Port connections G¼, G½, G⅜ for cable plug Type 2508 Operating voltage see type label Materials Body: Voltage tolerance ±10 % Identification MS Brass body, valve seat 1.4305 Nominal power 8 W operation, 85 W inrush brass body, brass valve seat Switching frequency max.
Intermittent operation for variant with AC/DC high-performance Type label (example) electronics Seat orifice Seal material Characteristics (acc. to DIN VDE 0580) Circuit function Body material cycle time Type – duty cycle – Connection, currentless break – pressure range relative duty ED –...
INSTALLATION Fluid installation Installation position: any, preferably coil or actuator face up. DANGER! → Clean pipelines and flange connections. Risk of injury from high pressure in the system. → Install dirt trap at the valve inlet (0.2...0.4 mm). ▶ Before loosening lines and valves, turn off the pressure and Note the flow direction of the valve.
Electrical installation Only for variant with terminal connection box: • Connect a maximum of one conductor per terminal point WARNING! • The maximum connection cable cross-section is 2.5 mm² / AWG 14 Risk of injury due to electric shock. • Remove insulation on the wires to a maximum length of 6 mm ▶...
MAINTENANCE, TROUBLESHOOTING Rotating the solenoid WARNING! WARNING! Risk of injury due to electric shock. Risk of injury due to improper maintenance work. ▶ Maintenance may be carried out by authorised technicians only If there is no protective conductor function between the coil and and with the appropriate tools.
DISASSEMBLY TRANSPORTATION, STORAGE, DISPOSAL DANGER! NOTE! Risk of injury from high pressure in the system. Transport damage. ▶ Before loosening lines and valves, turn off the pressure and drain the lines! Inadequately protected devices may be damaged during Risk of injury due to electric shock. transport.