General mounting considerations
9-3
General mounting considerations
9-3-1
Additional Guarding
9-3-2
Mechanical installation
9-3-3
Additional mounting rigidity
Areas of access to the point of hazardous operation not guarded by the F3S-
TGR-CL system must be protected by suitable means such as a fixed barrier
guard, an interlocked guard or a safety mat system.
The F3S-TGR-CL system is mechanically installed by using the T-slots on the
two sides or the back-side of the housing.
Use the movable bolts, washers, growers and nuts to fix the mounting brack-
ets as shown in the picture
ID
Description
1
movable M6 bolt
2
fixing braket
3
M6 washer
4
M6 Grower
5
M6 nut
It is recommended that the distance between the mounting brackets is
400 mm or less for optimum performance of the F3S-TGR-CL system.
Section 9-3
21