Pre-reset function

11-4 Pre-reset function
!WARNING
36
This function is only available on the F3S-TGR-CL_A - models.
The Pre-reset function is an addition to the manual restart function. It can be
used, where the operator doing the restart is not able to see the entire dan-
gerous zone.
The pre-reset pushbutton must be installed in the dangerous zone from where
the operator is able to check that nobody else is in the dangerous zone before
the manual restart function is used. Failure to do so may result in serious
injury.
The time limit between pre-reset and manual reset is 8 sec.
Fence
SLC
Pre - Reset
Reset
Note • Pre-reset function sets the F3S-TGR-CL system to manual reset mode.
• Blanking function can not be selected using pre-reset function.
• Muting function can not be selected using pre-reset function.
Wiring diagram:
Note If both inputs Muting A and Muting B loose +24 V, the F3S-TGR-CL system
changes to error condition
RECEIVER
PIN
2
7
1
3
SCH.
BROWN BLUE WHITE GREEN YELLOW RED GRAY PINK
Section 11-4