Function Manifold Valve Schematic (Aluminum) - J&M Speed Tender Pro Manual

Table of Contents

Advertisement

5 - Function Manifold Valve Schematic (Aluminum)

Conveyor
Conveyor
Front
Up/Down
Swing
Door
Use a good set of Allen wrenches when changing orifices.
The cartridge should be tightened with 25 ft-lbs of torque.
The coil nut should be tightened with 5 ft-lbs of torque.
There is a spring, poppet valve, and ball bearing at the bottom of each coil.
The top coil operates the bottom port.
The bottom coil operates the top port.
When changing cartridge make sure all functions are at rest.
The lettering on the coils should always be facing up.
Valve Bank Harnesses
The image on the right shows the valve
bank harness (JM0041057) that is used
on black, gold, blue, and silver 2014 and
newer valve banks. It also shows what the
connectors are for.
The harness on the left (JM0073932) is only
used on units with the Intercomp or WC3
remote.
Silver valve banks will have the harness tied
directly to it.
Conveyor
Rear
On/O
Door
P
E
D
F
A
C
G
B
H
K
J
Connector
JM0041055
PRINT
EXPORT
HOLD
SCALE
MENU
SETUP
TARE
CONTROLS
GROSS
NET
M+
Load Cells
JM0073932
Letter
Function
A
N/A
N
B
N/A
C
Conveyor Swing Front
M
D
Conveyor Swing Rear
E
Conveyor Up
F
Conveyor Down
L
G
Rear Door Up
H
Front Door Down
J
Power
K
Front Door Up
L
Rear Door Down
M
N/A
N
Conveyor Start
P
Ground
16030
WC3-D
START
TALC
UP
LIGHTS
POSITION
ENGINE
STOP
BIN
LEFT
CONV
RIGHT
CONTROLS
CONTROLS
RM
UP
DOWN
UP
UP
OPEN
DOOR 1
DOOR 2
ROLL TARP
DOWN
SHIFT
DOWN
CLOSE
JM0041057
OPEN
CLOSE
SHIFT
JM0041056
27