1. Locate wall bracket mounting position relative
to wall studs (Fig. 8). Install the supplied
wall bracket with six 3/8" diameter fasteners
(Fig. 10.1).
Note: Three holes are available at each fastening
site to allow capture of studs or supports
within the wall.
2. Locate and cut utility hole (Fig. 10.2) in wall
using Fig. 9 dimensions.
3. Rough in utilities. Wall mount bracket
dimensions can be used as a template.
§ Water: 1/2" FNPT
§ Drain: 3/4" MPT
4. Lift dispenser onto wall bracket positioning
unit so that hook on back of dispenser is
captured by wall bracket support angle
(Fig. 10.3).
5. Install two 1/4" X 20 screws through bottom of
wall bracket into bottom of dispenser to secure
dispenser to wall bracket (Fig. 10.4).
6. Install supplied 1/2" MPT X 3/8" push-in
adapter onto 1/2" FNPT water supply.
Fig. 9 – Wall mount, utility location
1.43" (3.6 mm)
3.99" (10.1 cm)
POTABLE WATER
3/8 COPPER TUBE
6.70" (17.0 cm)
POWER CORD EXIT
10.69" (27.1 cm)
3/4 COPPER TUBE
FRONT VIEW
0.77" (2.0 cm)
Fig. 8 – Wall bracket location guide
1.00" (25 mm)
2.00" (51 mm)
ANCHOR POINTS
0.438" (11 mm)
CLEARANCE
12.37" (31.4 cm)
3.44" (8.7 cm)
3.53" (9.0 cm)
Fig. 10 – Wall mount bracket and fastener
requirements
1
2
4
25CI425A/W, 25HI425A, 50CI425A/W, 50HI425A
TOP VIEW
WALL STUDS
FRONT VIEW
WALL STUDS
25HI425A
13" (33.0 cm)
50HI425A
15" (38.1 cm)
16.00"
0.75"
(406 mm)
(19 mm)
25HI425A
19" (48.3 cm)
50HI425A
21" (53.3 cm)
6.00"
(15.2 cm)
WALL CUTOUT