ATS Connection (if capable)

Using CAT5 (or better) cable, make an RJ45 connector, referring to the figure below, and connect to the ATS.
Make sure the AC circuit breaker, PV switch, and DC circuit breaker of the battery are disconnected before
starting electrical cable connections.
RJ45 Pin out (T-568B Standard)
Recommended
Pin
Wire Color
1
White-Orange
2
Orange
3
White-Green
4
Blue
5
White-Blue
6
Green
7
White-Brown
8
Brown
* Cable type : CAT5 UTP or better
ATS
Not Connected
Not Connected
ATS_K3
ATS_K14
Not Connected
ATS_EN
12V
GND