LG LGE ESS Home 6 Installation Manual page 127

Energy storage system
Table of Contents

Advertisement

Code Message
P221 Grid Underfrequency
P222 Grid Frequency Change
P225 Residual Current
P234 Grid DC Offset Current
P240 Anti-Islanding Detection
P253 Grid Over Voltage 10 min
P300 Battery Overvoltage (Batt1)
P310 Battery Undervoltage (Batt1) The voltage level of BAT A is lower
P320 Battery Over Current (Batt1) The current level of BAT A is higher
P330 Battery Over Current Instant
(Batt1)
P350 Battery Low SoC Trip (Batt1) The SoC level of BAT A is lower than
P351 Battery State Fault (Batt1)
P353 Battery Sleep (Batt1)
P354 Battery Power Down (Batt1) BAT A power is turned off
P370 DC-Link Overvoltage
P372 DC-Link Undervoltage
P400 PV Overvoltage (PV1)
P401 PV Overvoltage (PV2)
P420 PV Overcurrent (PV1)
Description
The frequency level of the grid is
lower than the lower limit
The amount of frequency change is
higher than the limit
The residual current is higher than the
limit
DC offset current is added to the grid Automatically restart after
There was a power failure
The average voltage of the grid for 10
minutes is higher than the limit
The voltage level of BAT A is higher
than the limit
than the lower limit
than the limit
The current level of BAT A suddenly
spikes above the limit
the lower limit
A State Error occurs in BAT A
BAT A power goes into power saving
mode
The voltage level of the DC Link is
higher than the limit
The voltage level of the DC Link is
lower than the lower limit
The voltage level of the PV1 is higher
than the limit
The voltage level of the PV2 is higher
than the limit
The current level of the PV1 is higher
than the limit
Troubleshooting
127
Solution
Automatically restart after
grid frequency is normal
Automatically restart after
grid frequency is normal
Automatically restart after
residual current is normal
detecting fault
Automatically restart after
detecting fault
Automatically restart after
grid voltage is normal
Automatically restart after
BAT A voltage is normal
Automatically restart after
BAT A voltage is normal
Automatically restart after
BAT A current is normal
Automatically restart after
BAT A current is normal
Automatically restart after
BAT A SoC is normal
Automatically restart after
BAT A state is normal
Automatically restart after
BAT A black start operation
is normal
Automatically restart after
BAT A black start operation
is normal
Automatically restart after
DC-Link voltage is normal
Automatically restart after
DC-Link voltage is normal
Automatically restart after
PV1 voltage is normal
Automatically restart after
PV2 voltage is normal
Automatically restart after
PV1 current is normal
4