O/P current distortion (THD i)
Power Factor
Operational voltage range
Setting)
Disconnection time of excess
operational voltage range
for
Operational frequency range
Germany
Setting)
(DE)
Disconnection time of excess
operational frequency range
Re-connecting time after
disconnection
Operational voltage range
Setting)
Disconnection time of excess
operational voltage range
Operational frequency range
for Italy
Setting)
(IT)
Disconnection time of excess
operational frequency range
Re-connecting time after
disconnection
Efficiency
Max. conversion efficiency
European efficiency
General Data
Topology
Power consumption:
standby / night
Protection degree
3
Regulation voltage range is 184~264.5 V
4
Regulation frequency range is 47.5~50.2Hz according to VDE0126-1-1.
5
Regulation voltage range is 184~267 V
6
Regulation frequency range is 49.7~50.3Hz according to ENEL Guide 2010.
Model
3
(F/W
4
5
(F/W
6
AC
AC
(F/W
Min Voltage protection 0.2 s; Max voltage
(F/W
Transformer-less
according to VDE0126-1-1
according to ENEL Guide 2010
47
47
CPS SC4.6KTL-O
< 3%
> 0.99
190~256V
≦0.2 sec.
47.55~50.15Hz
≦0.2 sec.
30 sec
190~267V
protection 0.1s
49.75~50.25Hz
≦0.1 sec.
60 sec
96%
94%
< 8W /
< 0.1W
IP65
Need help?