Atlas Copco GA 37+ Instruction Book page 85

Oil-injected screw compressors
Hide thumbs Also See for GA 37+:
Table of Contents

Advertisement

Instruction book
Period
Daily
3-monthly (1)
Yearly
Table 5: Maintenance checklist
(1): More frequently when operating in a dusty atmosphere
Programmed service interventions
Apart from the above mentioned actions, a number of service interventions (see the table below)
are programmed in the controller. Each plan has a programmed time interval at which all service
actions belonging to that plan are to be carried out. When reaching the interval, a message will
appear on the screen indicating which service plans are to be carried out.
See section
Service menu
After servicing, the intervals must be reset.
Check measured parameters
Record SPM measurements
Change the air filter
Change the electric cabinet filter
mats
Change the oil
Change the oil filter
Change the oil separator element
2920 7196 21
Operation
Check oil level.
Check readings on the controller display.
Check the air filter service indicator.
Check that condensate is discharged during operation of the compressor.
Drain condensate.
Check the pressure dew point temperature (on compressors with integrated
dryer).
Check coolers. Clean if necessary.
Check cooling fins of electric motor(s). Clean if necessary.
Remove the air filter element and inspect. If necessary, clean using an air jet.
Replace damaged or heavily contaminated elements.
Check the filter element of the electric cabinet. Replace if necessary.
On compressors with integrated dryer:
Stop the compressor, close the air outlet valve and switch off the voltage.
Remove any dirt from the condenser inlet with a vacuum cleaner.
Next, clean with an air jet in the reverse direction of the normal flow. Use low
pressure air. Keep the compressed air nozzle more than 30 cm away from
the condenser to avoid damaging the condenser fins.
Remove dust from inside the dryer, e.g. with a vacuum cleaner.
Do not use water or solvents to clean the condenser.
Check the condition of all hoses. Replace if necessary.
for compressors with an Elektronikon
A-service
Every 4000
running hours (1)
x
x
x
x
x (3)
x (3)
Touch controller.
B-service
D-Service
Every 8000
Every 24000
running hours (2)
running hours
x
x
x
x
x
x
x
x
x
x
x
x
x
x
83

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ga 45+

Table of Contents