Download Print this page
WATSON Tonic Bench User Manual

WATSON Tonic Bench User Manual

Advertisement

Quick Links

Tonic Bench
US ER GUI D E

Advertisement

loading

Summary of Contents for WATSON Tonic Bench

  • Page 1 Tonic Bench US ER GUI D E...
  • Page 2: Important Safety Instructions

    IMPORTANT SAFETY INSTRUCTIONS This product is for commercial use only. DANGER To reduce the risk of electric shock, always unplug this furnishing from the electrical outlet before cleaning. WARNING To reduce the risk of burns, fire, electric shock, or injury to persons: Unplug from outlet before putting on or taking off parts.
  • Page 3: Care & Maintenance

    CARE + MAINTENANCE Surface & Case • Caustic solutions containing greater than 2% lye, Laminate such as Drano® To clean the surface, use mild soap or detergent with • Sodium bisulfate, such as Sani-Flush® a damp cloth or sponge. Difficult stains such as coffee •...
  • Page 4 Tonic arranges users into a simple or fully electric linear dual-sided bench table format that supports power outlets, data channel and many functional elements. The Tonic Bench Table unit features a modular power distribution 8-wire, four circuit manufactured wiring harness system. Tonic modular power distribution is based on a power raceway furnishing consisting of a power raceway, power blocks, preconfigured outlets, jumper cables between power blocks, and power feed for hardwire connection to building power supply.
  • Page 5: Technical Specifications

    TECHNICAL SPECIFICATIONS Four 20-amp circuits, 8 wire configuration. 3 hots (12 gauge) sharing one neutral (10 gauge) and one ground. 1 hot (12 gauge) with one neutral (10 gauge) and one ground. Four 20-amp circuits, 8 wire configuration. 2 sets of 2 hots (12 gauge), each set with one neutral (10 gauge) and one ground.
  • Page 6 26246 Twelve Trees Lane NW, Poulsbo, Washington 98370 TNC USER GUIDE | 5 800.426.1202 watsonfurniture.com info@watsonfg.com...
  • Page 7: Wiring Schematic

    WIRING SCHEMATIC 1 20 / 2 4 0V 1 p h FOR 2+2 USE CIRCUITS 1, 3 , 4 ONLY MAX 20AMPS PER CIRCUIT FOR 3+1 USE CIRCUITS 1, 3, 4 ONLY MAXIMUM SEGMENTS CONNECTED: CIRCUIT 2 CAN NOT BE UTILIZED 12 STANDARD POWER WITH 120/240V 6 HEAVY POWER...