SMC Networks PF3A701H Operation Manual page 45

Digital flow switch
Hide thumbs Also See for PF3A701H:
Table of Contents

Advertisement

Select analogue output free range
function
Press the ▲ or ▼ button to select
analogue output free setting function.
[on] Free range function
ON is selected
Press the S button to set
value input.
Input of set value
Use the ▲ or ▼ buttons to
set the flow value that will
output 5 V (10 V) or 20 mA.
The entered flow value can be in the range: 10% of the
max. rated flow, to the upper display limit.
Press the S button to set.
[oFF] Free range function
OFF is selected.
Press the S button to return
to function selection mode.
Return to function selection
mode.
[F 5] FUNC setting completed
-45-
No.PF※※-OMX0007-B