Assa Abloy Corbin Russwin IN100 Series Installation Instructions Manual page 13

Multi-point lock
Hide thumbs Also See for Corbin Russwin IN100 Series:
Table of Contents

Advertisement

IN100 Series
FE6600/BL6600/MP6600
Multi-Point Lock
4
Lock Installation (Continued)
6
Install Outside Reader (Continued)
h. Secure the following connectors to their respective terminals
(Figure 6D):
CAUTION: Do not touch or allow debris to enter connector
contacts.
Secure 4-pin DPS connector
Secure 10-pin lock body assembly connector
Secure (*optional) 2-pin external 12-24VDC power connector
Secure (*optional) external 12-24VDC power supply
ground ring terminal to Ground Lug
NOTE: For UL294 applications, the power supply shall be
UL294 Listed, Class 2 Power Limited
NOTE: For ULC-60839-11-1 applications, the power supply
shall be ULC-60839-11-1 (Security Grade Level 2 or better)
Listed Class 2, or ULC-S319 (Security Grade Level 2 or better)
Listed Class 2, or ULC-S318 Listed, Class 2
NOTE: For ULC-60839-11-1 applications the power supply
wiring shall be a maximum length of 3 meters (9.8 feet)
IMPORTANT: Do not run wires through bottom flange hole
in plate - it will damage wires and controller connector.
Route wires around flange. (See Figures 6D-F)
i. When all connections have been made, tuck excess
cable into wire hole on inside of door.
j. Secure mounting assembly while ensuring proper
alignment of outside reader and tighten two (2)
through-bolts on inside of door to secure reader.
(Figure 6E)
k. Secure 24-pin card reader connector. (Figure 6F)
Board-to-Board
Connector
DPS (4-pin)
for Lockbody
Reader (24-pin)
Fig. 6F
FM558 09/23
Remote Power Harness Wire Terminations
Connector
Ring Terminal
Power Supply (PS) Required - UL Class 2 Filtered
& Regulated, 12-24VDC, 1.0A
Ground
Lug
*If 12-24VDC power
harness used, secure its
ground (ring terminal)
here as well
13
Copyright © 2020-2023, ASSA ABLOY Access and Egress Hardware Group, Inc.
All rights reserved. Reproduction in whole or in part without the express written permission
of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
*Optional 12-24VDC Power
2-pin
Black
PS (-) Return
Red
PS (+) 12-24VDC
Green Earth Ground
12-24VDC
Power*
DPS (4-pin)
- -
+ +
Lock Body
Fig. 6D
(10-pin)
Fig. 6E
Fully
tighten