IN100 Series
FE6600/BL6600/MP6600
Multi-Point Lock
4
Lock Installation (Continued)
9
Install Inside Cover (Figure 12)
a. Assemble cover by hooking top
b. Carefully press bottom of cover
c. Secure cover utilizing 1/8"
10
Install Shield
a. Install shield (provided) over inside controller. (Figure 13)
b. Drill and tap door for #8-32 machine screws (provided).
IMPORTANT: Read the following before continuing with installation
Please refer to FM440 FE6600 & BL6600 MultiPoint Lock Installation Instructions before
continuing with this installation if (optional) Dogging Indicator is being installed.
edge on inside mounting plate.
toward door without pinching or
damaging wires.
security hex key.
NOTE: Use of power tools on this step is strongly
discouraged. Over-torquing security pin
hex screw will result in battery cover damage.
FM558 09/23
NOTE: Slots face up
15
Copyright © 2020-2023, ASSA ABLOY Access and Egress Hardware Group, Inc.