❶ Installation

1.1 I Selecting the location

1.1.1 Installation precautions
• The appliance should be installed at a distance of at least 2 metres from the edge of the pool.
• Do not lift the appliance by the body; use its base.
• The appliance can only be installed outdoors : provide free space around it (see § "1.1.2 Selecting the location").
• Place the appliance on its anti-vibration pads (supplied with appliance) on a stable, solid and level surface.
• The surface must be able to bear the weight of the appliance (in particular in the case of installation on a roof, a
balcony or any other support).
• The appliance may be secured to the ground using the holes in the base of the appliance or with rails (not supplied).
View of the appliance base from below for installing the anti-vibration pads
The appliance must not be installed:
• In a closed and unventilated room,
• In a location where it would be subject to snow build-up,
• In a location where it might be flooded by the condensates produced by the appliance when operating.
• In a location subject to high winds,
• With the blowing towards a permanent or temporary obstacle (awning, brushwood, etc.) less than 2,5 metres away,
• On brackets,
• Within range of water or mud jets, sprays or run-off (take the effect of the wind into account),
• Near a heat source or flammable gas,
• Near high-frequency equipment,
Tip: to reduce noise produced by your heat pump
• Do not install it under or facing a window.
• Do not tilt it towards your neighbours.
• Install the appliance in an open space (sound waves are reflected on surfaces).
• Install an acoustic screen around the heat pump, respecting the distances (see § "1.2 I Hydraulic
connections").
• Install 50cm of flexible PVC pipe at the heat pump water inlet and outlet (to stop vibrations).
: Front
: Rear
: Anti-vibration pads