Quick Guide

6. User Interface

This chapter is to introduce the user interface and the parameter of UTE310 digital meter.
6.1 Description of Display Icon
Display Contents
U-RANGE 15V /30V /150V /300V /600V
U-AUTO 15V /30V /150V /300V /600V
I-RANGE 5mA/10mA/20mA/50mA
/100mA/200mA/500mA/1A/2A/5A/10A/20A
I-AUTO 5mA/10mA/20mA/50mA
/100mA/200mA/500mA/1A/2A/5A/10A/20A
I-RANGE 2.5V/5V/10V
I-AUTO 2.5V/5V/10V
I-RANGE
50mV/100mV/200mV/500mV/1V/2V
I-AUTO
50mV/100mV/200mV/500mV/1V/2V
RMS/DC/MN
SYNC.OFF
Instruments.uni-trend.com
EXT1
EXT2
SCALE
L.F
F.F
Indicates that the voltage is a fixed range of 15V /30V /150V /300V /600V
respectively (each range is one-half of the current range when CF=6 or 6A).
Indicates that the voltage is an automatic range of 15V /30V /150V /300V
/600V respectively (each range is one-half of the current range when CF=6
or 6A).
Indicates that the current is a fixed range of 5mA /10mA /20mA /50mA
/100mA /200mA /500mA /1A /2A /5A /10A / 20A (each range is one-half of
the current range when CF=6 or 6A).
Indicates that the current is an automatic range of 5mA/ 10mA /20mA
/50mA /100mA /200mA /500mA /1A /2A /5A /10A / 20A respectively (each
range is one-half of the current range when CF=6 or 6A).
Indicates that the current selection is EXT1 (the external current sensor 1).
Indicates that the current selection is is EXT2 (the external current sensor
2).
Indicates that the current is fixed range 2.5V /5V /10V of EXT1 respectively
(each range is one-half of the current range when CF=6 or 6A).
Indicates that the current is automatic range 2.5V /5V /10V of EXT1
respectively 2.5V/ 5V/ 10V (each range is one-half of the current range when
CF=6 or 6A).
Indicates that the current is fixed range 50mV/ 100mV/ 200mV/ 500mV/ 1V/
2V of EXT2 respectively. 50mV/100mV/200mV/500mV/1V/2V (each range is
one-half of the current range when CF=6 or 6A).
Indicates that the current is automatic range 50mV/ 100mV/ 200mV/
500mV/ 1V/ 2V of EXT2 respectively. 50mV/100mV/200mV/500mV/1V/2V
(each range is one-half of the current range when CF=6 or 6A).
Indicates that the scaling transformation is enabled.
Indicates that the line filter is enabled.
Indicates that the frequency filter is enabled.
Indicates that the measurement mode is RMS/DC/MN.
Indicates that the synchronous source is not set.
Function Description
UTE310 Digital Power Meter
16 / 38