Pit Boss PB1600PSE Manual page 8

Hide thumbs Also See for PB1600PSE:
Table of Contents

Advertisement

Available languages

Available languages

L
Settings
The Setting options under this screen:
• Display: Select the brightness of the display or select
the temperature scale. Fahrenheit (ºF) is the default.
• Screen Saver: The default is 15 Min. Select 1 Min, 3
Min, or 5 Min to choose when the display will go into
sleep mode after it has been idle, and click Lock to
confirm. Press the Control Knob to wake the display.
• Start-Up: OFF is the default and will automatically
heat the unit to 225°F. Touch the screen or move the
Control Knob to temperature (it will be blinking blue)
and rotate the wheel to modify, press the Control Knob
to confirm the temperatureor touch anywher on the
screen. Select ON to keep this selected temperature as
the new start-up temperature. The temperature range
is 180-500°F.
• Language: English is the default. French and Spanish
are selectable options.
• About: The information of the unit will be displayed
here. Name, Model No., Serial No., Controller ID,
Version, and MAC (Media Access Control) Address.
L
O Smoke Mode
In the Settings menu and select P Setting to access the
Grill sub-screen. In the sub-screen, choose Smoke Mode.
Selecting Smoke Mode allows the user to directly control
the cycle rate of pellets that feed the burn pot. In Smoke
Mode, the auger can run a manual cooking mode based
on the P Setting value selected if the Set temperature is
65°C/150°F, or it can run the predefined auger values for
other Set temperatures above 65°C/150°F. The default
P Setting value is P-4. On this setting, the grill will feed
pellets for 18 seconds and pause for 115 seconds. In most
instances, you will want to keep the P Setting on the
default.
• Raising the P Setting to P-5, P-6, or P-7 increases the
pause time between each feeding of pellets to the
burn pot. A higher P Setting is useful in warmer or
hot environments that want to hot smoke but the
ambient outdoor temperature amplifies the cooking
temperature inside the grill. Note: Monitor your burn
pot closely, as raising the P Setting too high or too
quickly may cause the fire to die out completely.
PIT BOSS® GRILLS
M Menu
The Menu options: Hold Prime, 3 Seconds Prime,
or 5 Seconds Prime. Selecting the Hold option will
continuously feed pellets from the auger, 30 seconds
maximum. Press it again to stop the auger feed. The
timed selections will prime automatically for that period.
N Light Switch
Press this button to switch on and off the light inside
the grill barrel.
• Lowering the P Setting to P-3, P-2, P-1, or P-0 will
decrease the pause time between each feeding of
pellets to the burn pot. A lower P Setting is used
to compensate for cooler temperatures where the
ambient outdoor temperature reduces or weakens the
intensity of heat produced inside the grill. Lowering
the P Setting can also minimize temperature swings in
varying outdoor weather conditions.
For the best smoke flavor, set your smoke temperature
below 121°C/250°F and choose the Smoke Mode from the
P Setting menu.
P PID Mode
In the Settings menu and select P Setting to access the
Grill sub-screen. PID Mode is the default and regular
mode of operation. This allows the Grill Probe (tem-
perature sensor) to control how much fuel is required to
attain and maintain the desired Set temperature. The
advantage of this cooking method is the ability to main-
tain the Set temperature by reducing the swings caused
by external temperature and user interactions (with the
grill). The temperature range is 65-260°C/150-500°F, at
5°F degree increments.
8
HAVE A
QUESTION?
Check out some
common FAQs online
or Live Chat with
Customer Care.
O
P
WWW.PITBOSS-GRILLS.COM

Advertisement

Table of Contents
loading

This manual is also suitable for:

10982

Table of Contents