Error tree: Unit has lost the calibration
Service error: 90
Unit type: iCombi Classic
Display Service 90
Unit has lost calibration. Is mainly shown when commissioning the unit.
Was the self test carried out when commissioning the unit?
Activate under "General settings" - "Self test".
No
Switch off the unit
Switch on the unit
Self test is started automatically
In the service level, go to "General settings"
Switch off under "General settings" - "Self test".
Service error: 90