Error tree: Solenoid valve Y2 does not open
Service error: 42.2
Unit type: iCombi
Check that the latest unit software is installed on the
unit.
Service error: 42.2
Service error 42.2
Check the solenoid valve Y2 in the function test under
service level (TECLEVEL).
Does the CDS sensor count up
when the Y2 is activated?
No
Is water flowing through the control box?
(see in the basket during water drainage).
No
Check the water feed and the control solenoid for
calcification.
Problem solved?
Remove the side panel of the
unit.
Check the connectors on the solenoid valve
block and on the I/O board to ensure that they
are connected correctly to the contacts.
Disconnect the connector on the solenoid valve
block and check the input voltage with a
multimeter on the contact of the white cable.
1
1
Note on the iCareSystem module test:
Select service level (TECLEVEL) -> "CleanJet & Care" launcher -
> "Module test" tab -> "Module test iCareSystem".
Yes
Run the iCareSytem module test.
Once complete, return to the start screen.
Yes
Replace the solenoid valve.
Yes
End
End
V01 · 05/2021 · RTS/Shof · en-GB