Error tree: Cooling circuit is not working properly, board temperature is over
80 °C
Service error: 29
Unit type: iCombi
Check the maximum temperature of the board in the diagnosis
Cooling fan runs when Cooking Mode is selected and the door is closed
Service error: 29
Cooling circuit is not working properly, board temperature is over 80 °C
Maximum temperature over 80°C
YES
Check cooling fan
No
Display service 29
Check, clean or replace air filter