1
If Y14 is
"On",
Repeat the voltage
230 V must be measured between the
No
measurement on the contact
Is 230 V measured here?
No
Replace the I/O board.
contact (brown cable) and neutral.
X19 on the I/O board.
Is this the case?
Yes
Yes
Check the cable connection and
End
replace if necessary.
Check the hose running from the CleanJet solenoid
valve Y14 to the CleanJet nozzle for blockage and
remove if necessary.
Replace the solenoid valve block.
End