Predefined absolute value for relative programs (P21)
Start program (P
program (P
) or in an absolute manner, as desired.
A
Function active (P21 = 1)
•
Absolute parameter setting
Function inactive (P21 = 0)
•
Relative parameter setting (ex factory)
Electronic gas flow control, type (P22)
Active only in machines with integrated gas flow control (option ex works).
Adjustment may only be carried out by authorised service personnel (basic setting = 1).
Program settings for relative programs (P23)
The start, down-slope and end program relative programs can be set individually or combined for the P0-
P15 operating points. When choosing the combined setting, in contrast to the individual setting, the
parameter values are saved in the JOB With the individual setting, the parameter values are identical for
all JOBs (except for special JOBs SP1,SP2 and SP3).
Correction or nominal voltage display (P24)
When setting the arc correction using the right-hand rotary knob the display will either show the correction
voltage +- 9.9 V (ex works) or the absolute nominal voltage.
099-005392-EW501
01.02.2016
), down-slope program (P
START
Design and function
Special parameters (advanced settings)
) and end program (P
B
END
) can be set relative to the main
97