5.5.11.6 Example, visible seams (latched super pulse)

Basic parameters
Welding parameter
GASstr
GASend:
RUECK
"P
" start program
START
Welding parameter
DVstart
ustart
tstart
"P
" main program
A
Welding parameter
tS1
DV3
t2
tS3
"P
" reduced main program
B
Welding parameter
tS2
DV3
U3
t3
"P
" end-crater program
END
Welding parameter
tSend
DVend
Uend
tend
099-005392-EW501
01.02.2016
Figure 5-39
Meaning / explanation
Gas pre-flow time
Gas post-flow time
Wire burn-back length
Meaning / explanation
Wire speed
Arc length correction
Duration
Meaning / explanation
Slope duration from P
START
Setting the wire speed
Duration
Slope duration from P
to P
B
Meaning / explanation
Slope duration from P
to P
A
Wire speed
Arc length correction
Duration
Meaning / explanation
Slope duration from P
or P
A
Wire speed
Arc length correction
Duration
Design and function
to P
A
A
B
to P
B
END
MIG/MAG welding
Setting range
0.0s to 20.0s
0.0s to 20.0s
2 to 500
Setting range
0% to 200%
-9.9V to +9.9V
0.0s to 20s
Setting range
0.0s to 20s
0% to 200%
0.1s to 20s
0.0s to 20s
Setting range
0.0s to 20s
0% to 200%
-9.9V to +9.9V
0.1s to 20s
Setting range
0.0s to 20s
0% to 200%
-9.9V to +9.9V
0.0s to 20s
65