Hotstart; Antistick; Parameter Overview - EWM drive 4X HP Operating Instructions Manual

Wire feed unit
Table of Contents

Advertisement

5.7.4

Hotstart

The hotstart device improves the ignition of the stick electrodes using an increased ignition current.
a) =
Hotstart time
b) =
Hotstart current
I =
Welding current
t =
Time
For hotstart parameter settings, - See 5.7.6 Parameter overview chapter
5.7.5

Antistick

5.7.6

Parameter overview

Basic parameters
Item
Meaning/explanation
1
Welding current
2
Hotstart time
3
Hotstart current
The hotstart current is a percentage based on the welding current selected.
099-005392-EW501
01.02.2016
Figure 5-52
Anti-stick prevents the electrode from annealing.
If the electrode sticks in spite of the Arcforce device, the machine
automatically switches over to the minimum current within about 1
second to prevent the electrode from overheating. Check the welding
current setting and correct according to the welding task!
Figure 5-53
Figure 5-54
Design and function
Setting range
5 A to maximum welding current
0 to 20 s
0 to 200 %
MMA welding
81