Testing Procedures
To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless
testing requires power.
Illustration
Cooling sail switch
Select switch
Pressure regulator
Hot wire relay
H2
S
H1
L
R
Pulser
Clean timer
Clean Relays
K-1, K-3, K-4
Terminal Block
16
!
Component
Measure continuity of switch positions:
Closed ..............................................
Open .................................................
Disconnect wires and test for
continuity per wiring diagram.
Verify gas pressure (WCP).
If on LP service, verify proper gas
supply conversion.
Disconnect wire leads and measure
resistance of terminals:
Check resistances of terminals:
R - S....................................................
Disconnect wire leads and measure
resistance of terminals:
Check continuity of terminals: .............
Verify supply voltage ...........................
Disconnect wires and test for
continuity.
Check resistances of terminals:
A - B.................................................
Disconnect wires and test for
continuity per wiring diagram.
WARNING
Test Procedure
16026509
Results
Continuity
Infinite
See wiring diagram for schematic layout.
Input
Output
7 - 9
Nat.
5
Nat.
"
"
11 -14
L.P.
10
"
"
Approximately 1700
If component does not indicate continuity
with wires disconnected, replace.
Continuity
Verify terminals not shorted to chassis
120 VAC
All relays are use for clean cycle.
Approximately 1700
See wiring diagram for schematic layout.