3. Check for Stored Energy: At the applicator, press the "Air-Only" once, pull the trigger. No activity
should be present at the machine.
4. Isolation Verification: Does the machine have electric power or compressed air present? The
power button should not be lit; it should be off. At the applicator, press the "Air-Only" once, pull
the trigger. No activity should be present at the machine.
5. Verify the reason for using the Lockout Tagout procedure has been solved. Once you
verify that the problem is solved, follow the instructions in the
this manual.
System Description
Dimensions
Machine Weight
Dry Ice Capacity
Variable Feed Rate
Power Consumption
Feeder Drive
Blast Pressure Range
Supply Pressure Range
Air Consumption Range
Blast Pressure Range
Click to go to Top of Document
Machine Data
22 x 16 x 21 in (560 x 410 x 530 mm)
130 lb. (59 kg)
For 6 x 6 x 12 in (150 x 150 x 300 mm) blocks – 24.5 lb. (11 kg)
For 5 x 5 x 12 in (127 x 127 x300 mm) blocks with inserts – 16.5 lb. (7.5 kg)
0 – 1.2 lb./min (0-0.6 kg/min)
100 – 140 VAC, 1PH, 60 Hz, 300 W
200 – 240 VAC, 1 PH, 50 Hz, 300 W
¼ Hp, 1.1 A. 230 VAC, 750 RPM, AC Motor
20 – 140 psi (1.4 – 9.7 bar)
50 – 140 psi (3.4 – 9.7 bar)
12-50 cfm @ 100 psi (0.3 – 1.4 m3/min @ 6.9 bar)
20 - 145 psi (1.4 - 10 bar)
Starting the Machine
11
section of
2023-12-13
Need help?
Do you have a question about the i3 MICROCLEAN and is the answer not in the manual?