Sv9100 Automatic Dim Log File Export From The Gcd-Cp10; Dimlog; Dimlast; Record Live System Activity To Usb - NEC UNIVERGE SV9100 System Maintenance Manual

Hide thumbs Also See for UNIVERGE SV9100:
Table of Contents

Advertisement

UNIVERGE SV9100

SV9100 Automatic DIM Log File Export from the GCD-CP10

A new facility has been made available to make diagnostics simpler.
For advanced analysis NEC engineers often ask for a Diagnostic (DIM) log.
On the SV8100 this would be gained by taking a PC to site to connect to the SV8100 and record these.
On the SV9100 the DIM log is automatically saved as text data to SD-Card on CPU, removing the need for an
external PC.
The saved DIM log can be extracted to USB flash drive or can be saved to PC via PC programming.
DIM Files are created automatically by the SV9100 System
Up to 100MB can be stored to the SD card installed to the GCD-CP00 card.
These files cannot be deleted from the SD card; new files will automatically overwrite older files as
necessary.
The function doesn't need any license.
As for Debug command of DIM, commands below are "ON" in the initial state.
・mail in 0 0 0 0 (caps)
・mail in 0 0 1 2 (isdn)
Debug commands can be changed to ON/OFF via Web programming

DIMLOG

System Log file.
Used by NEC Japan to show detailed system information. New file created when the system is reset.
File name format is an incrementing value (DIMLAST1.txt)

DIMLAST

Historical system activity.
Saves the system activity into 4MB files, a new file is created when current file reaches 4MB or when the
system is reset.
File name format is the date and time the file was created (DIMLOG_YYMMDDhhmm.txt)
The detail of the DIMLAST is determined by the setting of the DIM commands as shown in this document, eg
to enable ISDN Debug use 'mail in 0 0 1 2'.

Record Live System Activity to USB

System Activity can also be saved live to the USB using the Maintenance Service Code (CMD 10-11-42).