10

READING SV9100 DIM TRACES

ECTION
The DIM trace can be partly decoded by the engineer but only NEC Infrontia Japan can decode the
full trace.
This section describes the basic decode to enable the engineer to identify the extension and trunk port
number.
Extensions
o
Each extension type has a unique logical port type as shown below.
The port number is identified by the four digits (in hexadecimal) following the logical port type. The four
digits are 0000 to ffff hexadecimal (00 to 65535 in decimal).
(example: keytelephone port 1 will be 00040001 as shown below.)
>>>> PORT : 0401H STATUS 0000H => 0002H
Trunks
o
Each trunk type has a unique logical port type as shown below.
The port number is identified by the four digits (in hexadecimal) following the logical port type. The four
digits are 0000 to ffff hexadecimal (00 to 65535 in decimal).
(example: ISDN port 17 will be 00340011 as shown below.)
>>>> PORT : 00340011H STATUS 00D0H => 00B1H
System Maintenance Manual
Type
Key telephone
SLIU
S-Point
DECT
Type
COIU
ISDN
Logical ID
0004
0000
004c
00e9
Logical ID
000c
0034
Issue 1.0