UNIVERGE SV9100
Go to Flowchart C1.
Check to see if station is call
forwarded or in DID.
Yes
Station in
Call Forward
or DID?
Cancel
feature.
Reset/replace station, then
reset or replace CD-8DLCA.
Yes
Send terminal in
for repair.
System Maintenance Manual
Multiline Terminal Ringing Problems
Intermittent
Problem?
Check to see if problem occurs on CO or internal
calls (including station-to-station or transferred
calls).
Internal
Problem?
Both
Check and adjust volume
control, and test again.
No
Problem
Solved?
No
Reset/replace station,
then reset or replace
G CD-8DLCA.
Problem
Solved?
No
No
Problem
Solved?
D2
Consistent
CO
Check PRG 15-07.
Check PRG 22-04 for ring
assignment.
Yes
Done.
Yes
Done.
1.
Perform Second Initialization, and test.
2.
Perform First Initialization, and test.
3.
Replace GCD-CP10, and test
Yes
Wrong
Program
Assignment?
again.
No
Yes
Wrong
Program
Assignment?
again.
No
Issue 1.0